Vega SI-12 / User Manual 
 

 

29

 

Revision 12 – 03 July 2020 

 

6 STORAGE AND TRANSPORTATION REQUIREMENTS 

Vega  SI-12 pulse counter shall be stored in the  original packaging in heated room at 

temper5°С to +40°С and relative humidity less than 85%. 

The device transportation is permissible in covered freight compartments of all types at 

any distance at temperatures -40°C to +85°C.  

Содержание SI-12

Страница 1: ...www vega absolute ru LoRaWAN Pulse Counter VEGA SI 12 User manual...

Страница 2: ...6 16 08 2017 PKP Adding s in alarm command description 07 07 09 2017 KEV Part Vega LoRaWAN Configurator was added 08 18 10 2017 KEV Warranty conditions was changed minor edits 09 04 05 2018 KEV Edits...

Страница 3: ...up 11 External devices connection 12 Connecting via USB 13 4 VEGA LORAWAN CONFIGURATOR 14 Interface of the application 14 Connection to the device 15 Device info tab 16 LoRaWAN settings tab 18 Vega SI...

Страница 4: ...To provide the stable radio between the gateway and the end device it is recommend avoiding the device installation in the places which are barriers for the radio signal getting through like a reinfor...

Страница 5: ...ithium thionyl chloride LiSOCl2 battery Attempts to charge the battery may result in fire COMUNICATION AND DATA COLLECTION ALGORITHM The readings collecting from the meter with a configurable period f...

Страница 6: ...ed packets configurable o Simultaneous readings from 4 independent inputs o Two operating modes Active and Storage o Inputs switching to the Security mode for connection of leakage safety and other ex...

Страница 7: ...868 based Activation type ABP or OTAA Communication period 5 15 30 minutes 1 6 12 or 24 hours Data collection period 5 15 30 minutes 1 6 12 or 24 hours Memory amount for storing packets 200 packets Ty...

Страница 8: ...ontact Designation Power 5V Power IN1 IN2 IN3 IN4 Pulse inputs Signal ground out 1 out 2 Open collector outputs 1 and 2 Ground contacts are used for connection of pulse inputs IN1 IN2 IN3 and IN4 The...

Страница 9: ...Configurator software when connected to the counter via USB In this case the device does not count pulses at the Security input but only monitors its closure Should the Security input close the devic...

Страница 10: ...N network and when the operating modes are changed LED signal Meaning Series of short flashings Linking to the network One long flashing The device connected to the network and is in active mode Three...

Страница 11: ...ressing the start button the device immediately starts working in the Active mode 2 OTAA After pressing the start button the device makes three attempts to connect to the network within the set freque...

Страница 12: ...N The actuators are connected to the counter via outputs out 1 out 2 which are of the type Open drain Permissible load for each digital output is 2 A To increase the load on the device outputs it is n...

Страница 13: ...the driver for the COM port stsw stm32102 which can be downloaded from iotvega com After running the executable file VCP_V1 4 0_Setup exe the installer window will appear In this window you need to cl...

Страница 14: ...check the coverage area of the signal from the gateways are available Next the work of the application is considered in the Expert mode INTERFACE OF THE APPLICATION The Vega LoRaWAN Configurator appl...

Страница 15: ...he Connect button in the menu on the left The application automatically recognizes the type of device and the device selection menu becomes inactive To read the settings from the device you need to cl...

Страница 16: ...ds information about the device model its firmware and automatically corrects the device s time when connected to it Update firmware allows you to select the firmware file from your computer s hard dr...

Страница 17: ...number of gateways that received this signal and the signal quality This button only works when the device is connected to the network Device output not displayed in the Simple mode monitoring the de...

Страница 18: ...based In the device frequency plan only those channels are active by default on which sending requests for connection to the network join channels The remaining channels that the device should use ca...

Страница 19: ...nfirmation or until the Uplink number of transmission is over see below If you choose to send packets without confirmation the modem will not know whether the packet delivered or not ADR this option a...

Страница 20: ...work while OTAA mode active The second window always opens after 1 second after the first Uplink number of transmission not displayed in the Simple mode if the Confirmed uplinks function is disabled t...

Страница 21: ...djusted to this value when sending packets to the LoRaWAN network This option can be changed by the network server TX datarate not displayed in the Simple mode the device transmission datarate at whic...

Страница 22: ...ing the button on the board for a long time more than 5 seconds see section Initial startup Input settings allow you to change the operation of the pulse inputs from the counting of pulses to the secu...

Страница 23: ...e device starts sending accumulated packets with readings from the earliest to the latest With the Confirmed uplinks option turned on the device will send the next packet only after receiving a confir...

Страница 24: ...epending on the type number of pulses or status 0 open 1 closed uint32 4 bytes Input 2 reading depending on the type number of pulses or status 0 open 1 closed uint32 4 bytes Input 3 reading depending...

Страница 25: ...t No where the alarm is detected 3 or 4 uint8 4 bytes Time of the modem at a moment of the packet transmission unixtime UTC uint32 4 bytes Input 1 reading depending on the type number of pulses or sta...

Страница 26: ...d description Data type 1 byte Packet type this packet 255 uint8 4 bytes Time of the modem at a moment of the packet transmission unixtime UTC uint32 After receiving this type of package the applicati...

Страница 27: ...uint8 1 byte Output on time in seconds 1 255 0 forever uint8 3 Output off command sent by application on LoRaWAN port 2 Size in bytes Field description Data type 1 byte Packet type this packet 4 uint...

Страница 28: ...uplinks 1 byte 1 confirmed 2 unconfirmed 8 Uplinks number of transmissions 1 byte from 1 to 15 12 Input 1 mode 1 byte 1 pulse 2 guard 13 Input 2 mode 1 byte 1 pulse 2 guard 14 Input 3 mode 1 byte 1 p...

Страница 29: ...QUIREMENTS Vega SI 12 pulse counter shall be stored in the original packaging in heated room at temperatures 5 to 40 and relative humidity less than 85 The device transportation is permissible in cove...

Страница 30: ...Vega SI 12 User Manual 30 Revision 12 03 July 2020 7 CONTENT OF THE PACKAGE The pulse counter is delivered complete with Vega SI 12 pulse counter 1 pc Screw 4 pcs Factory certificate 1 pc...

Страница 31: ...ecified in this user manual Warranty does not apply to power supplies of devices sending more than 80 000 packets the device with mechanical electrical and or other damages and defects caused by viola...

Страница 32: ...Vega SI 12 User Manual 32 Revision 12 03 July 2020 vega absolute ru Operation Manual Vega Absolute OOO 2017 2020...

Отзывы: