background image

 

 

Vega SI-11 / User Manual 

 

 

22 

Revision 26 of 25 August 2021  

 

DOCUMENT INFORMATION 

Title 

Pulse Counter Vega SI-11 

Document type 

Manual – Translation from Russian 

Document number 

V02-SI11-01  

Revision and date 

26 of 25 August 2021  

 

Revision History 

Revision  Date 

Name  Comments 

01 

24.01.2017 

KEV 

Document creation date 

02 

26.01.2017 

PKP 

Little accuracies was removed 

03 

27.01.2017 

PKP 

Exchange protocol description was added 

04 

30.01.2017 

KEV 

General correction, formatting etc. 

05 

01.02.2017 

KEV 

The preface was added on the cover 

06 

07.03.2017 

PKP 

RU868 was added 

07 

17.03.2017 

KEV 

New photos, information about stickers, USB was added 

08 

14.04.2017 

KEV 

Minor edits 

09 

10.05.2017 

KEV 

New photos of the appearance  

10 

01.06.2017 

PKP 

Minor edits at the communication protocol  

11 

17.06.2017 

PKP 

Fixed error in archive request command 

12 

11.07.2017 

PKP 

Fixed error in protocol description 

13 

16.08.2017 

PKP 

Adding’s in alarm command description 

14 

08.09.2017 

KEV 

Part “Vega LoRaWAN Configurator” was added 

15 

11.10.2017 

KEV 

Warranty was changed, minor edits 

16 

10.01.2018 

KEV 

Minor edits, new illustrations in the “Operation” part 

17 

04.05.2018 

KEV 

Edits concerning the field of application with meters 
with pulse outputs 

18 

24.07.2018 

KEV 

Changes in the device logic, removed switches, added 
frequency plans, changes in the communication 
protocol, in technical characteristics 

19 

03.09.2018 
 
 
 
 
 

PKP 
KEV 

Changes in the communication protocol. Timestamp is 
added to the alarm packet. 
Pulse input scheme is added. 

20 

22.01.2019 

KEV 

Communication protocol

 changed, device 

setting “by 

the air”

 added, 

device AppEui

 added in specification, 

Marking

 part added, other inaccuracies fixed 

21 

24.01.2019 

KEV 

Inaccuracy in 

communication protocol

 fixed – packet 

type for packets with settings and request of settings 

22 

19.12.2019 
 
 
 

KEV 

Fixed inaccuracy about frequency of alarm packets 
generation, minor changes 

Содержание SI-11

Страница 1: ...www vega absolute ru PULSE COUNTER VEGA SI 11 USER MANUAL DOCUMENT REVISION FIRMWARE VERSION 26 2 4...

Страница 2: ...LED Indications 11 Mounting Recomendations 12 4 COMMUNICATION PROTOCOL 14 Vega SI 11 pulse counter transmits the following types of packets 14 1 Packet with current readings 14 2 Alarm packet 15 3 Pa...

Страница 3: ...ation on powering and activation procedure control commands and functions of the counter This manual is targeted at specialists familiar with installation work fundamentals of electronic and electrica...

Страница 4: ...t in fire OPERATION ALGORITHM Vega SI 11 operates in modes listed below Storage is a mode for storing and transporting In this mode the device does not communicate regularly with the network Active is...

Страница 5: ...m 5 minutes to 24 hours When beginning of communication session the device starts sending packets with readings from the earliest packet The time of data transmitting cannot be specified it s defined...

Страница 6: ...easuring of the built in battery MARKING Device marked with sticker that contain the next information Device name DevEUI Release Date Sticker located in three places on device case in factory certific...

Страница 7: ...mmunication period 5 15 30 minutes 1 6 12 or 24 hours Data collection period 5 15 30 minutes 1 6 12 or 24 hours Memory amount for storing packets 200 packets Type of the LoRaWAN antenna internal Sensi...

Страница 8: ...t Delay 5 seconds Uplink number of transmissions 1 Data rate DR0 Power 14 dBm Communication period 24 hours Data collection period 24 hours Time zone UTC 00 00 Inputs operate in mode pulse For changin...

Страница 9: ...mounting for DIN rail 1 screw 2 mm 8 mm cross 2 DIN rail with mounting holes 3 mm 3 silicone gasket without through holes ensuring the protection rating of the device case IP65 All of elements for ma...

Страница 10: ...t is not supported Polarity effects only open collector circuits To reset all readings from the pulse inputs accumulated in the device memory you need to switch the device to the Storage mode by holdi...

Страница 11: ...ANING Short flashings Linking to the network in progress One long flashing during 5 sec The device has been successfully connected to the network and is in active mode Three flashings each by 1 sec Li...

Страница 12: ...ed screwdriver awl wire stripper laptop Step by step mounting be like 1 Setting the devices and connecting them to the network are usually carried out in the office see Network Deployment Manual 2 Det...

Страница 13: ...device it is necessary to reset the pulses accumulated during testing and connection by switching the device to the Storage mode by pressing the button for 5 seconds 9 Start the device by pressing lau...

Страница 14: ...ing on the type number of pulses or status 0 open 1 closed uint32 4 bytes Input 2 reading depending on the type number of pulses or status 0 open 1 closed uint32 4 bytes Input 3 reading depending on t...

Страница 15: ...this packet 2 uint8 1 byte Battery charge uint8 1 byte Values of basic settings bit field uint8 1 byte Input No where the alarm is detected uint8 4 bytes Packet time unixtime UTC uint32 4 bytes Input...

Страница 16: ...en settings request command received or device connected to the network Size in bytes Field description Data type 1 byte Packet type this packet 0 uint8 2 bytes ID of parameter uint16 1 byte Data leng...

Страница 17: ...device sends the packet with settings 3 Packet with settings Is identical to such packet from device Size in bytes Field description Data type 1 byte Packet type this packet 0 uint8 2 bytes ID of para...

Страница 18: ...yte 1 pulse 2 guard 14 Input 3 mode 1 byte 1 pulse 2 guard 15 Input 4 mode 1 byte 1 pulse 2 guard 16 Communication period 1 byte 1 1 hour 2 6 hours 3 12 hours 4 24 hours 5 5 minutes 6 15 minutes 7 30...

Страница 19: ...ION REQUIREMENTS Vega SI 11 pulse counter shall be stored in the original packaging in heated room at temperatures 5 to 40 and relative humidity less than 85 The counter shall be transported in covere...

Страница 20: ...Vega SI 11 User Manual 20 Revision 26 of 25 August 2021 6 CONTENT OF THE PACKAGE The pulse counter is delivered complete with Vega SI 11 pulse counter 1 pc Screw 4 pcs Factory certificate 1 pc...

Страница 21: ...ory certificate the factory certificate does not have an TCD stamp and or there is no sticker with information about the device the serial number DevEUI EMEI printed on the product differs from the se...

Страница 22: ...17 PKP Fixed error in protocol description 13 16 08 2017 PKP Adding s in alarm command description 14 08 09 2017 KEV Part Vega LoRaWAN Configurator was added 15 11 10 2017 KEV Warranty was changed min...

Страница 23: ...ixed inaccuracy about data type in Temperature field minor changes 24 09 06 2020 KEV The battery information is changed in the specification 25 24 06 2021 KEV Scheduled revision of documentation New w...

Страница 24: ...Vega SI 11 User Manual 24 Revision 26 of 25 August 2021 vega absolute ru User Manual Vega Absolute OOO 2017 2021...

Отзывы: