15
7.
DEFAULT
OPENING PROFILE (M0)
PAR. TST800
Description
Default
o0
Start opening acceleration ramp
02
o1
End opening acceleration ramp
45
o2
Start opening deceleration ramp
55
o3
End opening deceleration ramp
98
o4
Coupling cam opening speed
08
o5
Maximum opening speed
60
o6
End opening speed
08
o7
Learning speed
12
CLOSING PROFILE (M1)
PAR. TST800
Description
Default
c0
Start closing acceleration ramp
98
c1
End closing acceleration ramp
55
c2
Start closing deceleration ramp
45
c3
End closing deceleration ramp
02
c4
Additional run closing for mobile coupling cam
01
c5
Starting closing speed
08
c6
Maximum closing speed
40
c7
End closing speed
08
c8
Speed during the initial synchronization
10
TORQUES (M2)
PAR. TST800
Description
Default
F0
Brake
50
F1
Limit Torque
20
F2
Stationary opening torque
01
F3
Stationary closing torque
01
F4
Security Torque in closing
35
F5
Security Torque in opening
40
OPTIONS (M3)
PAR. TST800
Description
Default
S0
Safety reopening system in closing
Slave (00)
S1
Safety reopening system in opening
Disabled (00)
S2
Command type (Master/slave)
Slave (00)
S3
Motor rotation (forward/reverse)
Forward (00)
S4
Auto racing
Disabled (00)
S5
Photocell Mode
Slave (00)
MECHANICAL PARAM. (M5)
PAR. TST800
Description
Default
M1
Motor Type
03
M2
Pulse/cm
06
LIGHT CURTAIN PAR. (M6)
PAR. TST800
Description
Default
G0
Light Curtain ON
NO (00)
G1
Anti vandal time
60
G2
Security Test
NO (00)
G3
Timeout security test
800 (80)
G4
Acoustic signal during Nudge command
YES (01)
G5
Acoustic signal during obstruction
NO (00)
EN81-20/50 PARAM. (M7)
PAR. TST800
Description
Default
P0
Enable Reopening when the CLOSE command is OFF
NO (00)
P1
Space of reopening (cm)
02
P2
Waiting time before of the repening (sec)
08
P3
Final space (cm) in which the limit switch is active
04