• If the framing and CRC-4 state of the received signal do not
match the framing and CRC-4 settings, the test set will display
Loss of Frame condition and may display loss of CRC DET.
CRC-4
Select yes to measure CRC-4 errors on the incoming signal and
also to transmit the CRC-4 bits on the outgoing signal. CRC-4
works with PCM-31 and PCM-30 framing only. If UNFRAME has
been selected, the CRC-4 configuration is NO.
TEST RATE
Options: 2.048M (F1), Nx64K (F2)
Select an appropriate rate for the circuit under test.
• 2.048M: Configure the test set for full rate testing. If uncertain
about which one to choose, select this for full rate testing.
• Nx64: Configure the test set
for fractional testing. Upon
pressing, the SELECT TIME
SLOT screen is displayed as
in the screen shown to the
right. In it, select each time
slot to test, these can be
selected automatically or
manually using the following
procedures:
11:50:50
>LINK DN- Idle
STU-C E1<
SELECT TIME SLOT
RECEIVE
01
02 03 04 05 06 07 08
09 10 11 12 13 14 15
17 18 19 20 21 22 23 24
25 26 27 28 29 30 31
TRANSMIT
01
02
03 04 05 06 07
08
09 10
11 12 13 14 15
17 18
19 20 21 22 23
24
25 26
27 28 29 30 31
AUTO SELECT UN-SEL CLR-ALL
Figure 29 Select Time Slot Screen
Manually Selecting Time Slots
1. Use to choose the time slot and press SELECT
(F2). Repeat until finished. Selected time slots remain high
-
lighted, as shown in Figure 29.
• Press UN-SEL (F3) to deselect a time slot.
• Press CLR-ALL (F4) to clear all selections and to start over.
Automatically Selecting Time Slots
1. Press AUTO (F1) if receiving a signal which is already format-
ted in the Nx64 kbit/s fractional E1 format.
In AUTO, the test set automatically configures time slots by
looking for active data. It will configure the transmit side to
be the same as the active time slots on the receive side. The
test set determines which time slots are active by first deter
-
mining which time slots are idle. Any time slot that is not idle
is assumed to be active.
In PCM-31 framing, time slots 1-31 correspond to channels 1-
31. In PCM-30 framing, time slots 1-15 correspond to channels
MTT-14B e_Manual D07-00-083P RevA00
Page 49 of 101