Trigger mode may only be initiated by a remote controller. In order for a controller to initiate the Trigger Mode, the
following steps must be followed:
1. The multiplexer output port (A or B) must be in REMOTE mode.
2. The host controller must download a valid Input Sequence Table containing a list of 2 to 255 Inputs
3. The controller must send an “Enable Sequence” command to the multiplexer. Following successful receipt of
this command the RF Input Indicators will either show the first input in the sequence table (Leading Update
mode) or will stay on the current channel (Trailing Update mode). (See AT1700 Protocol Specifications for
more details)
4. Sequenced operation is now ready. Each time the controller toggles the trigger line, the multiplexer will ad
-
vance to the next item in the table. Upon reaching the end of the table, the pointer will wrap around to the
first item.
The decimal point of the leftmost digit is illuminated to indicate that the unit is in TRIGGER mode.
Page 18 of 22
AT1700 series Manual D07-00-066P Rev. A00