To enter Program Mode, set the PGM input active (low) e.g. by tying it to COM.
Whilst in Program Mode, the PGM indicator will be ON.

Function

Pre-scaler

Out Time

Decimal Point

Operator Mode:

Preset

Parameter

Description

(Upper Display)

None

Meaning

Pre-scales counter operation

(multiply from 0.001 to 9.999)

Value = Count units displayed

      Count pulses input

Sets momentary ON time for

PRESET output (0.01 - 99.99s; 

0.00 for latched operation)

Defines decimal point position

Shows Preset value

NOTES

1. To adjust Pre-scaler, Out Time or Preset value (as selected), press Next

key to enter Edit Mode (digits will flash), use Next key to select each digit to

be adjusted, and adjust digit value using Down key. When adjustment is

complete, press 

ENT

 key to exit Edit Mode (digits will become static).

2. To adjust decimal point position, select that parameter, press Next key to

enter Edit Mode, then use Next key to position decimal point. Press 

ENT

 key 

when finished.

To exit Program Mode, set the PGM input inactive (High).

WARNING!
Changing Program
Mode parameter values 
while the process is
operating may be
hazardous to the
operator and/or the
controlled equipment.
Use extreme caution
and stop the process
before attempting to
change Program Mode
parameter values.

IMPORTANT

You must press the 

ENT

key to implement new
parameter values.

NOTE

Possible Decimal Point
Position settings are:

Содержание V454501

Страница 1: ...e V454500 family of preset counters combines state of the art circuitry and electronic assembly techniques with an ergonomic package design that results in the most cost effective high performance cou...

Страница 2: ...s display of Count and Preset data Red LED display Annunciators show input display and output status Ergonomic Keypad Simple key sequences to view and edit Presets Front Panel Reset key can be disable...

Страница 3: ...Current Sinking NPN Count Inputs Connect Add count input to Terminal 2 A and or Subtract count input to Terminal 3 B see below In Configuration Mode set PuLL parameter to YES and for Add Subtract oper...

Страница 4: ...rom the front of the mounting panel and hold the Counter lightly in position against the panel Ensure that the panel gasket is not distorted and that the Controller is positioned squarely against the...

Страница 5: ...ting left most digit will start to flash and to move between the digits Once the proper digit is selected flashing with the Next key its value can be altered through use of the Down key Program Mode U...

Страница 6: ...ts are as required press the ENT key to confirm the changes the display will stop flashing IMPORTANT You must press the ENT key within 15 seconds of the last keypress when entering a new value otherwi...

Страница 7: ...e digits will flash use Next key to select each digit to be adjusted and adjust digit value using Down key When adjustment is complete press ENT key to exit Edit Mode digits will become static 2 To ad...

Страница 8: ...a parameter use the Down key to step through the parameters when the desired parameter description is shown in the upper display press the Next key to enter Edit Mode and to scroll through the availab...

Страница 9: ...medium speed 25 0ms low speed Control Inputs Remote Reset Terminal 5 edge sensitive Program Mode Terminal 6 level sensitive Input Voltage High 3 0V or open Low 2 0V Input Impedance 4 7k to V Input Re...

Страница 10: ...10 N O T E S...

Страница 11: ...11 N O T E S...

Страница 12: ...Neuhausen ADF Tel 49 71589003 0 Fax 49 71589003 32 In Brazil Veeder Root do Brasil Rua Ado Benatti No 92 Caixa Postal 8343 CEP 05037 010 S o Paulo Tel 55 118612155 Fax 55 118611982 1675 N Delany Road...

Отзывы: