9
Console Installation
Wiring the Console
Wiring the Console
1. Pull four wires between the power panel and the console; three #14 AWG (2.5 mm
2
) color-coded wires for AC line
(L), AC neutral (N) and chassis ground; and one #12 AWG (4 mm
2
) green and yellow wire for barrier ground.
For international applications using 240 Vac, pull four wires between the power panel and a 5 A fused, switched,
neon indication spur; three #14 AWG color-coded wires for AC line (L), AC neutral (N) and chassis ground; and one
#12 AWG green and yellow wire for barrier ground. Pull four identical wires between the spur and the console.
2. Open the right door of the console and connect the four power/ground wires as shown in [Figure 4]. Do not connect
the power wires to breaker panel at this time.
Figure 4. Wiring AC Power to the Console
WARNING
The console contains voltages which can be lethal. It is connected to devices
that must be intrinsically safe.
Connecting power wires to a live circuit can cause electrical shock that may
result in serious injury or death.
1. Turn power off at the circuit breaker connecting the power supply wires.
2. Attach conduit from the power panel to the console's Power Area
knockouts only (1 on top and bottom, ref. Figure 3).
OFF
12
3
4
OPEN
+
PROBE 6
+
PROBE 5
+
PROBE 4
+
PROBE 3
+
PROBE 2
+
PROBE 1
WARNING
SUBSTITUTION OF COMPONENTS
MAY IMPAIR INTRINSIC SAFETY.
NO REPAIRS SHOULD BE ATTEMPTED.
REFER SERVICING TO QUALIFIED
PERSONNEL ONLY.
AVERTISSEMENT
LA SUBSTITUTION DE COMPOSANTS
PEUT COMPROMETTRE LA SECURITE
INTRINSEQUE.
J4
J5
SW1
SEC
SETUP
J3
CONSOLE
POWER
RELAY RATING
120/240 VAC
2 A MAX
consoles\tls50\50powr.eps
Protective Earthing
Conductor (Green and
Yellow) Attach #12AWG
(4 mm
2
) barrier ground
wire to ground lug
Attach neutral wire to top
terminal ("N") of J4
Attach hot wire to bottom
terminal ("L") of J4
Attach chassis ground
wire to ground lug
Power
Side
Intrinsically
Safe Side
POWER WIRING NOTES:
1. Barrier ground must be #12 AWG (4 mm
2
)
or larger diameter.
2. Check to be sure that the electrical resistance
between the console ground lug and a known
good earth ground is less than 1 ohm.
3. Connect the power supply wires in the power
panel to a separate dedicated circuit.
4. Electrical rating power input -- 120 Vac or
240 Vac, 50/60 Hz, 2 A maximum.
5. See the "Console Dimensions and Designated
Conduit Knockouts" figure for actual locations of
power conduit knockouts into the console. Power
wiring must enter only in Power Area conduit
knockouts.
N
L
C24
C27
L2 L4
WARNING!
Shock hazard. Do not
touch metal ends of
capacitors C24/C27
or the metal bands
on chokes L2/L4.