MAG-XL Flex Probe Installation
Unpack the MAG-XL Flex Probe
16
Figure 6. Attaching conduit hangers to battery mounting bracket
4.
Get the customer supplied outdoor junction box and the customer supplied 3/4” x 1/2” reducing bushing and
screw it into the top threaded opening of the junction box until tight.
5.
Get the customer supplied length of 1/2” conduit and screw it in the reducing bushing until tight.
6.
Get the 1/2” brass hex adapter from the probe installation kit and after orienting the embossed arrow down,
screw it onto the other end of the 1/2” conduit until it is tight.
7.
Take the battery support assembly, the junction box/conduit assembly and the transmitter to the top of the tank
for final assembly on the 2-inch tank fitting.
Unpack the MAG-XL Flex Probe
CAUTION!
• DO NOT CUT THE TIE WRAPS that hold the coiled MAG-XL Flex Probe together before installation.
• DO NOT BEND THE TOP 2 FEET OF THE MAG-XL Flex Probe. The top of the MAG-XL Flex Probe has
electronic components inside of the tube and must remain straight (see Figure 7).
• ALWAYS KEEP THE COILS PARALLEL. When the tie wraps are removed, do not lift one coil separately from
the other coils. Never twist one coil 90 degrees from the other coils. See Figure 8.
LEGEND FOR NUMBERED BOXES IN Figure 6
1.
2-inch or 4-inch conduit hanger [as required] - 2 places
2.
1/4 x 20 hex head nut - 4 places
3.
1/4 x 20 x 1.25” hex head bolt - 2 places
4.
Battery pack support bracket
5.
1/4 x 20 x 0.5” hex head bolt - 2 places
972-7.ep
s
2
3
5
4
3
1