C35799 Rev. 04/25/03
Page 2
SETUP INSTRUCTIONS FOR C05899 – CREDIT/DEBIT NETWORK MODEM
The modem already comes factory-programmed with the correct command strings and you should typically never need to
perform this configuration. Skip to the section
CFN Router Configurations
.
The C05899 Credit/Debit Card Network Modem is for Site Controller II, Site Controller III, or Islander II with a network interface
which requires the fuel management system to contact a credit or debit network for verification of a user’s card. This modem
is identified by the following manufacturers and model numbers:
•
GASBOY Quick Connect Network Modem – Multitech Model MT2834ZDXb
•
Zoom – Model 2948L, 2949L
•
Hayes Accura – Model 4703US
•
Boca Research – Model M024ED
Important: Modems to be used for dial-out to a bank network require a dedicated phone line.
Configuring for use as a Credit/Debit Card Network Modem
•
If this modem is connected to a CFN system, use the diskette supplied with the modem to run the configuration utility,
PROGMODM.CMD. Insert the diskette into the A: drive and type
A:PROGMODM
. Follow the instructions in
PROGMODM for configuring as a bank network modem.
•
If you do not have the diskette containing the PROGMODM.CMD utility, follow the procedure below. The
↵
symbol
means press the ENTER key and the 0’s are zeros, not the letter O. Follow steps 1 and 2 for all modems, then perform
the command in the chart for your specific modem.
1. Connect a terminal to the modem with a 1:1 cable male DB-25 to male DB-25
(C04549)
or male DB-25 to female
DB-9
(C04654)
. The terminal must be configured at the baud rate at which the modem will operate.
2. Type:
AT&F&W
↵
↵
Modem response: No response from Gasboy Quick Connect. All others respond with OK.
Modem
Baud Rate
Command
1200
Type:
ATE0Q0V0X4&B1&Q1&D2&E3$MB1200S0=0S6=1S11=60&W
↵
↵
Modem response: 0
Gasboy Quick Connect
2400
Type:
ATE0Q0V0X4&B1&Q1&D2&E3$MB2400S0=0S6=1S11=60&W
↵
↵
Modem response: 0
1200
Type:
ATV0E0X4\N1S0=0S37=5S7=255S11=70&K0%C0&W
↵
↵
Modem response: 0
Zoom
2400
Type:
ATV0E0X4\N1S0=0S37=6S7=255S11=70&K0%C0&W
↵
↵
Modem response: 0
Boca Research
1200 or 2400
Type:
ATV0X0E0L1&Q0&D2&C1&S0&W
↵
↵
Modem response: 0
Hayes
1200 or 2400
Type:
ATV0X0Q0E0M1S0=0S7=255S9=6&Q6&K0&W
↵
↵
Modem response: 0
The modem is now ready for testing. The settings are saved and power may be turned off without losing the configuration.
CFN Router Configurations
Most CFN network routers use a
MODEMS.INI
file. Older versions of
MODEMS.INI
do not support the Gasboy Quick
Connect modem. If your site controller is running SCII software V2.3F and below, or SCIII 3.3F and below, copy the
MODEMS.INI
file from the supplied diskette into the BIN directory in the site controller
. DO NOT copy the file if you are
running SCIII V3.4 or above, or the router will not function.
After the file is copied, select the new modem from the
router configuration menu.
If the router you are using does not use a
MODEMS.INI
file, do not bother copying the file from the diskette. Just choose the
correct modem in the router’s configuration menu. If the correct modem is not listed, choose
Hayes 1200
for any of these
modems.