background image

2

R

5

6

7

8

4

3

2

1

O V E R V I E W

OPERATION

VEEDER-ROOT

1. Total Display

2. Down Key

3. Next/Reset Key

12345678

VEEDER-ROOT

3.  Next/Reset Key:  

If the total value is being displayed depressing

this key will cause the value to be reset to 0.  When the program input
is active this key is used to select a menu item for editing (left most
digit will begin to flash) and then move to the desired digit to be
changed.

1. Total Display:   

Indicates the present count value, which is equal to

the number of pulses received (since the last reset) multiplied by the
Count Input Calibrator in Program mode.

2. Down Key:

  When the program input is active this key is used to

scroll through the menu items.  After a menu item has been chosen for
editing, the down key is used to set the value for the currently selected
(flashing) digit.

REAR TERMINAL CONNECTIONS

* For high speed current sinking devices, provide a pull-up
resistor from terminal 2 to a DC source

1. Common

2. High Speed Input A  - PNP or squre

signals up to 10 kHz* for incrementing the
count value

3. Low Speed Input A - NPN or dry contact

inputs up to 30 Hz for incrementing the
count value

 4. Remote Reset - Resets count value when

switched to common

5. Front Panel Program Enable - Allows access to

program mode when tied to common

6. Low Speed Input B  - NPN or dry contact inputs up

to 30 Hz for decrementing the count value

7. High Speed Input B - PNP or squre signals up to 10

kHz* for decrementing the count value

8. DC Supply Input - For backlighting

Refer to wiring
for terminal 3

Refer to wiring
for terminal 2

+
-

10 - 28 VDC

+
-