background image

Care and cleaning

TERRAPIN-1.0en

7

Care and cleaning

The devices performance and 
serviceability are conditional on 
regular care and immediate 
attention to problems:
• Do not touch glass lenses 

with fingers.

• Do not soil the operating 

keys with oil or grease.

• Avoid abrupt temperature 

transition, since these can 
cause condensation 
moisture to develop inside 
the device.

The device does not need 
special care or cleansers.

Therefore
• do not use any kind of 

impregnated cloth intended 
for cleaning spectacle 
lenses,

• do not use any solvent 

except water, e.g. no alcohol 
or cleansers.

Lens cleaning

Particles of dirt should be blown 
off or removed using a soft 
brush.
Finger prints may be cleaned 
first by wiping with a damp 
cloth, followed by soft, clean 
optical tissue or chamois 
leather.

Cleaning the casing

Wipe the casing with a damp 
cloth. Pay special attention to 
dirt and grease around the 
keys.
Blow out the device interface 
cable socket, and clean it 
carefully.
Allow the device to dry fully 
before packing.

Shop for Vectronix products online at:

1.877.766.5412

www.

SCOUTBASECAMP

.com

Содержание TERRAPIN

Страница 1: ...TERRAPIN User Manual English Version 1 0 VII 2010 Shop for Vectronix products online at 1 877 766 5412 www SCOUTBASECAMP com...

Страница 2: ...APIN is a pocket size handheld button operated laser rangefinder with an internal sighting optic and range display For safe use of the device please note the safety directions included in the User Man...

Страница 3: ...he batteries 11 Diopter adjustment 12 Reticle 13 General Operations 14 Distance Measurements 15 Factors affecting measurement range 15 Slope distance 16 Multiple object measurement 17 Configuration 18...

Страница 4: ...20 Distance gate 21 Set Factory Settings Reset to default 22 Built in Test 23 Troubleshooting 24 Equipment 26 Parts List 26 Accessories 27 Customer service 28 Quality system 29 Shop for Vectronix pro...

Страница 5: ...ar 0 meter Inappropriate use Device deployment without prior knowledge of the operating instructions and safety notices Changes and modifications to the device by the customer Use of third party acces...

Страница 6: ...uries Explosion hazard The battery must not be short circuited recharged mechanically modified placed in fire or heated above 85 C with the device Caution Use of controls or adjustments or performance...

Страница 7: ...any kind of impregnated cloth intended for cleaning spectacle lenses do not use any solvent except water e g no alcohol or cleansers Lens cleaning Particles of dirt should be blown off or removed usi...

Страница 8: ...0en 8 Technical Data Optics Configuration monocular Magnification 5x Objective diameter 24 mm Field of view 142mil 8 Focus fixed Dioptric setting 4dpt Shop for Vectronix products online at 1 877 766 5...

Страница 9: ...gefinder TERRAPIN TERRAPIN Laser type IR diode 905 nm Eye safety Class 1 Standard IEC 60825 1 Ed 2 0 2007 03 Range Performance 20m 2400m Specified Performance 1800m Accuracy 1 3m Beam divergence 0 4 x...

Страница 10: ...on 1m 1h Operational temperature range 35 C to 63 C 31 F to 145 F Storage temperature range without battery 40 C to 85 C 40 F to 185 F Weight with batteries 500g Dimensions length 128mm 5 0in width 10...

Страница 11: ...stops The device monitors the condition of the batteries If the display shows LobAt this indicates that the batteries are used up You can still get readings but the batteries need to be replaced The L...

Страница 12: ...n object farther than 100 m away and rotate the eyepiece to obtain a sharp image Standard setting 0 L If the device is being used by different people remember your personal diopter setting Shop for Ve...

Страница 13: ...esponds to 1 m spacing at a distance of 1 km Illuminated reticle An illuminated reticle can be activated for the use under poor lighting conditions To activate the illuminated reticle press and hold t...

Страница 14: ...ymbols press and hold key release key press and release key click L You can prolong the display period by holding down the range key while the result is displayed Hold the device steady during measure...

Страница 15: ...stance Measurements Factors affecting measurement range Reflective properties Size of the target Oblique surfaces Atmospheric conditions Vibration Lighting conditions Shop for Vectronix products onlin...

Страница 16: ...ss the distance button for at least one second Sight the object with the reticle Hold the instrument steady as you release the key The slope distance appears If is displayed the object lies outside th...

Страница 17: ...e 3dOn must be activated via the configuration menu see page 18 A flashing display indicates that more than one distance has been detected Click the distance key repeatedly to scroll through all obtai...

Страница 18: ...rapid succession ConF appears for a short instant Click the distance key until the desired setting appears L The various functions are described in detail on the following pages Click the function key...

Страница 19: ...ess which is needed only in combination with an attached night vision device L If the function is set to ntOn and the device is used in daylight condi tions the message ntOn is displayed for a short i...

Страница 20: ...imes in rapid succession Unit appears briefly Click the distance key until the desired unit appears Click the function key two times in rapid succession to store the selection The setting is not chang...

Страница 21: ...urrent setting e g OFF Click the distance key until the desired minimum distance appears e g 300m Setting OFF disables the distance gate Click the function key two times in rapid succession to store t...

Страница 22: ...function key two times again to store the default factory settings StorE dEFS appears If not done correctly the settings remain unchanged and OldC is displayed The default factory settings are Distanc...

Страница 23: ...efly the built in test starts automatically 1 Model PLrF05 2 Software version Soft e g 02 03 10 3 Display Test 00000m00 m 4 Memory test MEM Good or bad 5 Flash Test FLASH Good or bad 6 Voltage Test vo...

Страница 24: ...duces performance of batteries Warm up batteries Extreme heat shortens batteries life Do not store the batteries at temperature over 85 C is displayed after distance measurement Distance is outside th...

Страница 25: ...ion menu only the distance with the highest return signal is displayed Select 3dOn in the configuration menu see page 18 ntOn is displayed after a measurement The device is used during daylight condit...

Страница 26: ...6 Standard extent of delivery Spare parts 1 TERRAPIN 4 905 494 Eye cap 2 667 002 SEB51 lithium battery 3V CR123A 2x required 5 907 702 Battery cover 3 907 650 Pouch 6 725 020 Lanyard Shop for Vectron...

Страница 27: ...PIN 1 0en 27 Accessories 2 1 Optional 1 664 868 SST3 1 mini tripod non magnetic 2 729 452 SST3 2 mini tripod non magnetic with pan tilt head Shop for Vectronix products online at 1 877 766 5412 www SC...

Страница 28: ...1 Internet www vectronix ch Copyright Without the prior written permission of Vectronix this document may neither be copied in part or whole by mechanical photographic electronic or any other means th...

Страница 29: ...ernational standards for quality and quality management systems ISO 9001 and environmental management systems ISO 14001 Total Quality Management our commitment to total customer satisfaction Ask your...

Страница 30: ...and Copyright by Vectronix AG Heerbrugg Switzerland VI 2010 Vectronix AG CH 9435 Heerbrugg Switzerland Telephone 41 71 726 72 00 Fax 41 71 726 72 01 www vectronix ch Shop for Vectronix products online...

Отзывы: