background image

8 

 

Vector Lab Products Refrigerators and Freezers

Locking/Unlocking of the Keypad

The temperature controller is defaulted to lock out after 30 seconds without a key being pressed and will display 
“Loc” . To unlock the controller press the SET key for 1 second until “UnL” is displayed . The controller is now 
unlocked .

Viewing/Adjusting the Set Point

With the controller unlocked, press and release the SET key . The current Set Point will populate . Use the UP & 
DOWN arrows to the desired Set Point and again press the SET key to store .

Powering the Equipment ON.

Locate the power switch to the left of the controller and place in the ON position (I) .

Controller Set Up

Upon power up your controller will alarm RTC . This is instructing you to program the TIME/DATE .
Press and release any key to silence the alarm .
Check that the controller is not locked (LOC) . If locked press and hold any key for 1 second and (UNL) will 
DISPLAY .

Содержание VREF12-LB-RGD

Страница 1: ...ctor Lab Products Refrigerators and Freezers 01381983R00 801 Church Lane Easton PA 18040 USA Toll free 1 855 686 5592 www vectorlabproducts com Following installation please forward this manual to the...

Страница 2: ...tion 6 Controller Operation 7 Locking Unlocking of the Keypad 8 Viewing Adjusting the Set Point 8 Powering the Equipment ON 8 Controller Set Up 8 Defrosting 9 Door Switch 9 Cleaning 11 Interior Cleani...

Страница 3: ...are receiving Following is an explanation of the different item numbers Model Number Width inches Depth inches Height inches Ref Volume cu ft Set Point Temp Elec V Ph Hz Cooling Capacity Absorbed Powe...

Страница 4: ...ystem The back of the refrigerator should have 2 inches of clearance to allow for power cord clearance and ventilation on unit Electrical Specifications 115 V 60 Hz 1 phase Minimum circuit ampacity 15...

Страница 5: ...ditions other than those specified herewith The equipment is secured to a wooden pallet base wrapped in a plastic film and packaged into a three waves carton box The equipment must be handled using a...

Страница 6: ...to 3 N m Fig 2 2 4 Attach wall anchor brackets to wall using appropriate hardware and installation method suitable to application and local codes Fig 2 1 2 Remote Alarm Connection These units are equi...

Страница 7: ...Products voiding equipment warranty Refrigerators come pre programmed with a 4 C 39 2 F set point Standard operating temperature at default is 4 C to 6 C 39 2 F to 42 8 F If desired the refrigerator s...

Страница 8: ...ontroller unlocked press and release the SET key The current Set Point will populate Use the UP DOWN arrows to the desired Set Point and again press the SET key to store Powering the Equipment ON Loca...

Страница 9: ...f the defrost probe Pb2 experiences a failure or is out of spec the MAX time the unit will stay in a defrost cycle is 15 minutes If this occurs a dFd alarm will appear Upon termination of the defrost...

Страница 10: ...10 Vector Lab Products Refrigerators and Freezers Alarms...

Страница 11: ...or other non abrasive cleaner Annual Cleaning Removal of dust and other particulates from air intake areas and the condenser is important for proper operation Environments with large amounts of dust...

Страница 12: ...OMPRESSOR HOT GAS SOLENOID HOT GAS LINE EVAPORATOR CAPILLARY TUBE CONDENSER Refrigeration Diagram Freezers DRYER HIGH PRESSURE VAPOR LOW PRESSURE VAPOR HIGH PRESSURE LIQUID LOW PRESSURE LIQUID COMPRES...

Страница 13: ...Run winding 3 7 16 7 VREF12 LB RSD R290 2 5 oz 0 070 kg 29 psig 2 barg 146 5 psig 10 1 barg Start winding 13 35 Run winding 4 89 19 6 VREF25 LB RGD VREF25 LB LGD VREF25 LB RSD R290 3 2 oz 0 09 kg 37...

Страница 14: ...r 6 6 wire ties 1 Turn off power to unit and unplug 2 Remove fa ade hold down screws rotate fa ade and set safety latch 3 Disconnect terminal from back up battery 4 Carefully cut wire ties to provide...

Страница 15: ...ntroller 1 Firstly make sure that the main switch is turned off and the controller is not powered The controller has removable screw connection terminals blocks so unscrew at the maximum openings the...

Страница 16: ...amming key is correctly inserted into the controller terminal blocks Copy the parameters from the controller to the programming key 1 After the above steps 1 2 Press and hold the Copy key button until...

Страница 17: ...d press firmly in place 4 Open and close door checking for proper gasket seal without pinching against refrigerator Modular Refrigeration System Vector Lab Products Modular Refrigeration System allows...

Страница 18: ...ows for the operation of scientific equipment in climate controlled refrigerated conditions Since the cabinet is a closed environment we use a R290 gas monitor to ensure that the interior atmosphere I...

Страница 19: ...Vector Lab Products Refrigerators and Freezers 19 2 Connect the air sample tube to the factory installed connection...

Страница 20: ...he unit press the main power switch shown below and verify the 4 amp breaker is not tripped 4 A green and orange indicator will illuminate 5 Push the reset button the orange indicator light will turn...

Страница 21: ...gized If at anytime the sampled air rises above the LEL power is disconnected while an audible and visual alarm are energized When enegized during warmup a green LED will blink on the detector indicat...

Страница 22: ...lack White Black White Black White Black White Battery V N L Power supply 100 240Vac V Low Battery AC OK Output 12Vdc Battery 12V Brown Blue Ground Red Black Red Black Red Black Battery charger connec...

Страница 23: ...2 6 3 7 4 8 Black White Black White Black White Black White Black White Black White Battery V N L Power supply 100 240Vac V Low Battery AC OK Output 12Vdc Battery 12V Brown Blue Ground Red Black Red B...

Страница 24: ...24 Vector Lab Products Refrigerators and Freezers Replacement parts...

Страница 25: ...r Cord 01316140 1 18 Top Protection Grid 01398130 1 19 Probes Kit 01394220 1 20 Lighting Switch 01394360 1 21 Controller Requires Programming Key 01394410 1 Key Programming Celsius Vector Ref12 013982...

Страница 26: ...26 Vector Lab Products Refrigerators and Freezers...

Страница 27: ...01394030 3 22 Door Handle 01394113 1 23 Door Gasket 01394063 1 24 Glass Door 01394287 1 25 Hinging Kit 01394204 2 26 Strip Led 01394659 1 27 Battery Back Up Kit 01394212 1 28 Lock Latch 01398148 1 29...

Страница 28: ...28 Vector Lab Products Refrigerators and Freezers...

Страница 29: ...01394246 1 21 Main Switch Kit 01394238 1 22 Power Cord 01316140 1 23 Top Protection Grid 01398155 1 24 Probes Kit 01394220 1 25 Safety Fan 01394345 1 26 Battery Backup Protection Relay 01394394 1 27 C...

Страница 30: ...30 Vector Lab Products Refrigerators and Freezers...

Страница 31: ...Protection Grid 01398171 1 18 Probe Kit 01394220 1 21 Controller Requires Programming Key 01394410 1 Key Programming Celsius Vector Ref 30 01398312 Key Programming Fahrenheit Vector Ref 30 01398338 22...

Страница 32: ...32 Vector Lab Products Refrigerators and Freezers...

Страница 33: ...394246 1 16 Main Switch Kit 01394238 1 17 Power Cord 01316140 1 18 Top Protection Grid 01398171 1 20 Door Gasket 01394253 1 21 Door 01398189 1 22 Hinging Kit 01394121 1 23 Battery Back Up Kit 01394212...

Страница 34: ...34 Vector Lab Products Refrigerators and Freezers...

Страница 35: ...Protection Grid 01398197 1 20 Probe Kit 01394220 1 23 Lighting Switch 01394360 1 24 Controller Requires Programming Key 01394410 1 Key Programming Celsius Vector Ref 49 01398379 Key Programming Fahren...

Страница 36: ...36 Vector Lab Products Refrigerators and Freezers...

Страница 37: ...Switch Kit 01394238 1 19 Power Cord 01316140 1 20 Top Protection Grid 01398197 1 21 Probe Kit 01394220 1 24 Controller Requires Programming Key 01394410 1 Key Programming Celsius Vector Ref 49 013983...

Страница 38: ...38 Vector Lab Products Refrigerators and Freezers...

Страница 39: ...Power Cord 01316140 1 20 Top Protection Grid 01398197 1 21 Probe Kit 01394220 1 24 Controller Requires Programming Key 01394410 1 Key Programming Celsius Vector Ref 49 01398379 Key Programming Fahren...

Страница 40: ...40 Vector Lab Products Refrigerators and Freezers...

Страница 41: ...98197 1 20 Probe Kit 01394220 1 23 Lighting Switch 01394360 1 24 Controller Requires Programming Key 01394410 1 Key Programming Celsius Vector Ref 49 Sliding Door 01398353 Key Programming Fahrenheit V...

Страница 42: ...42 Vector Lab Products Refrigerators and Freezers...

Страница 43: ...94246 1 21 Main Switch Kit 01394238 1 22 Power Cord 01316140 1 23 Top Protection Grid 01398155 1 24 Probes Kit 01394220 1 25 Safety Fan 01394345 1 26 Battery Backup Protection Relay 01394394 1 27 Cont...

Страница 44: ...44 Vector Lab Products Refrigerators and Freezers...

Страница 45: ...01394246 2 18 Main Switch Kit 01394238 1 19 Power Cord 01316140 1 20 Top Protection Grid 01398213 1 21 Probe Kit 01394220 1 24 Controller Requires Programming Key 01394410 1 Key Programming Celsius Ve...

Страница 46: ...46 Vector Lab Products Refrigerators and Freezers...

Страница 47: ...19 Top Protection Grid 01398239 1 20 Top Protection Grid 01398247 1 21 Probe Kit 01394220 2 22 Lighting Switch 01394360 1 23 Controller Requires Programming Key 01394410 1 Key Programming Celsius Vec...

Страница 48: ...01381983R00 Vector Products LLC 02 21 801 Church Lane Easton PA 18040 USA Toll free 1 855 686 5592 www vectorlabproducts com...