FIGURE 3  FRONT PANEL

CONTROLS AND INDICATORS

FUNCTIONS

2/4/6 AMP - 

allows the user to select the charger rate based on battery size. This selection and actual battery charge

rate are monitored by the microprocessor and will stop charging if the rate is too fast or too slow for

battery size or condition.

INDICATORS

FAULT - 

Lights when the battery is not connected properly or not charable. 

Rev. Polarity 

- Lights when clamps are incorrectly connected to battery terminals. 

Charging Complete - 

Indicates Battery is charged.

Содержание VEC1086B

Страница 1: ...ly necessary Use of an improper extension cord could result in a risk of fire and electric shock If extension cord must be used make sure a Pins on plug of extension cord are the same number size and shape as those of plug on charger b Extension cord is properly wired and in good electrical condition and c Wire size is AWG 14 14 gauge to 100 feet and AWG 12 for distances over 100 feet 5 Do not ope...

Страница 2: ...cle to charge or to clean terminals always remove grounded terminal from battery first Make sure all accessories in the vehicle are off so as not to cause an arc 3 Clean battery terminals Be careful to keep corrosion from coming in contact with eyes or skin 4 Add distilled water in each cell until battery acid reaches manufacturer s specified level This helps purge excessive gas from cells Do not ...

Страница 3: ...the Negative battery post marked NEG N For side mounted battery connections the side mounted battery connections the Positive terminal is red the Negative terminal is black 2 Attach a 24 inch minimum length 6 AWG insulated battery cable to the Negative battery post marked NEG N 3 Connect the Positive RED battery clamp to the Positive battery connector marked POS P or red 4 Stand as far back from t...

Страница 4: ...rging voltage remains constant while the actual charging current is reduced to allow for the maximum proper internal chemical energy transfer Stage Three Top Off Charge voltage is automatically maintained and reduced to a predetermined level while current is adjusted for a safe effective battery charge level step down regulation mode Ideal for topping off batteries that have been in storage At the...

Страница 5: ...her information FIGURE 3 FRONT PANEL CONTROLS AND INDICATORS FUNCTIONS 2 4 6 AMP allows the user to select the charger rate based on battery size This selection and actual battery charge rate are monitored by the microprocessor and will stop charging if the rate is too fast or too slow for battery size or condition INDICATORS FAULT Lights when the battery is not connected properly or not charable ...

Страница 6: ...E If charging cycle is interrupted the charger will go to Standby mode Automatic float can only be achieved after charging is complete and circuit has not been interrupted GENERAL BATTERY SAFETY With minimal maintenance the VEC1086B 2 4 6 AMP Smart Battery Charger will provide years of dependable service Follow these simple steps to maintain the charger in optimum condition After each use clean th...

Страница 7: ...stimates of the time it takes to charge a battery refer to the following table for details Deep cycle batteries may need longer charging time It is recommended to repeat the charging cycle a second time beginning with the 2 AMP rate The following chart converts hydrometer readings into percent of charge values Refer to the chart below for approximate charging times SPECIFIC GRAVITY PERCENT OF CHAR...

Страница 8: ...ATIONS This warranty does not cover accessories bulbs fuses and batteries defects resulting from normal wear and tear including chips scratches abrasions discoloration or fading due to usage or exposure to sunlight accidents damage during shipping to our service facility alterations unauthorized use or repair neglect misuse abuse failure to follow instructions for care and maintenance fire flood a...