9
into the AC receptacle(s). The green LED indicator lights to indicate that the
inverter is functioning. Make sure the combined load requirement of your
equipment does not exceed 350SST watts.
The MAXX350SST is engineered to be connected directly to standard electrical
and electronic equipment in the manner described above. Do not connect the
Power Inverter to household or RV AC distribution wiring. Do not connect the
Power Inverter to any AC load circuit in which the neutral conductor is
connected to ground (earth) or to the negative of the DC (battery) source.
WARNING:
Do not connect to AC distribution wiring
CAUTION:
RECHARGEABLE APPLIANCES
Certain rechargeable devices are designed to be recharged by
plugging them directly into an AC receptacle. These devices may
damage the inverter. Do not use the inverter to recharge items that can
be plugged directly into an AC receptacle.
This problem does not occur with the majority of battery-operated
equipment. Most of these devices use a separate charger or transformer
that is plugged into an AC receptacle. The MAXX350SST is easily capable
of running most chargers and transformers.
4.4 PLACEMENT OF THE INVERTER
For best operating results, the inverter should be placed on a flat surface,
such as the ground, car floor or seat, or other solid surface. A power cord
measuring 3 feet (1.0 meter) has been provided for easy positioning of the
inverter. The inverter should only be used in locations that meet the
following criteria:
DRY - Do not allow water and/or other liquids to come into contact with
the MAXX350SST inverter.
COOL - Ambient air temperature should be between 30 degrees F (-1
degree C) non-condensing, and 105 degrees F (40 degrees C). Do not
place the inverter on or near a heating vent or any piece of equipment
which is generating heat above room temperature. Keep the inverter away
from direct sunlight, if at all possible.
VENTILATED - Keep the area surrounding the inverter clear to ensure free
air circulation around the unit. Do not place items on or over the inverter
during operation. A fan is helpful if the inverter is operating at maximum
power outputs for extended periods of time. The unit will shut down if the
internal temperature exceeds 90 degrees C. The unit will restart after it
cools.