background image

15

purchaser only, to be free of defects in materials and workmanship for two years from the

date of purchase without additional charge. The warranty does not extend to subsequent

purchasers or users. Vector Manufacturing, Ltd. will not be responsible for any amount of

damage in excess of the retail purchase price of the product under any circumstances.

Incidental and consequential damages are specifically excluded from coverage under this

warranty. This product is not intended for commercial use. This warranty does not apply

to accessories or damage to units from misuse or incorrect installation. Misuse includes

wiring or connecting to improper polarity power sources.

RETURN/REPAIR POLICY:

Defective products, other than accessories, may be returned

postage prepaid to Vector Manufacturing. Any defective product, other than accessories,

that is returned to Vector Manufacturing within 30 days of the date of purchase may be

replaced free of charge . If such a product is returned more than 30 days but less than two

years from the purchase date, Vector Manufacturing will repair the unit or, at its option,

replace it free of charge.

If the unit is repaired, new or reconditioned replacement parts may be used, 

at Vector Manufacturing’s option. A unit may be replaced with a new or reconditioned

unit of the same or comparable design. The repaired or replaced unit will then be

warranted under the terms of the remainder of the warranty period.

The customer is responsible for the shipping charges on all returned items. 

During the warranty period, Vector Manufacturing, Ltd. will be responsible for the return

shipping charges.

LIMITATIONS:

This warranty does not cover accessories, bulbs, fuses and 

batteries, defects resulting from normal wear and tear (including chips, scratches,

abrasions, discoloration or fading due to usage or exposure to sunlight), 

accidents, damage during shipping to our service facility, alterations, unauthorized

use or repair, neglect, misuse, abuse, failure to follow instructions for care and

maintenance, fire, flood and Acts of God.

If your problem is not covered by this warranty, call our Technical Support 

Department toll free 866-584-5504 or www.vectormfg.com for general 

repair information and charges if applicable.

STATE LAW RIGHTS:

This warranty gives you specific legal rights. Some states do not allow

limitations on how long an implied warranty lasts or the exclusion or limitation of

incidental or consequential damages, so the exclusions or limitations stated herein may not

apply. This warranty gives the purchaser specific legal rights; other rights, which vary from

state to state, may apply.

TO REQUEST WARRANTY SERVICE FOR THIS PRODUCT: Contact Vector Manufacturing

Technical Support by telephone, fax or mail. We suggest that you keep the original

packaging in case you need to ship the unit. When returning a product, include your

name, address, phone number, dated sales receipt (or copy), and a description of the

reason for return and product serial number. After replacing the unit, we will attempt to

return it to you within four weeks.

WARRANTY ACTIVATION:

Please complete Warranty Activation Card and

mail to Vector Manufacturing. Enter “VEC024” as Model and “400 Watt

Power Inverter” as Product Type. All Vector Manufacturing, Ltd. products must

be registered within 10 days of purchase. To activate this warranty, mail

completed registration form, a copy of the original sales receipt  to:

WARRANTY REGISTRATION

VECTOR MANUFACTURING, Ltd.

4140 S.W. 28th Way; Fort Lauderdale, Florida 33312

Содержание VEC024

Страница 1: ...AD AND UNDERSTAND ALL CAUTIONS WARNINGS INSTRUCTIONS AND PRODUCT LABELS PLUS YOUR VEHICLE S BATTERY MANUFACTURER GUIDELINES FAILURE TO DO SO COULD RESULT IN INJURY AND OR PROPERTY DAMAGE 4140 SW 28TH...

Страница 2: ...C plug connections and ring terminal connections 4 This is not a toy keep away from children CAUTIONS 1 Do not use with positive ground electrical systems the majority of modern automobiles RVs trucks...

Страница 3: ...ION 6 4 1 Power Source Requirements 6 7 4 2 Connection to Power Source 7 8 4 3 Connection to Load 8 9 4 4 Placement of Inverter 9 5 OPERATING TIPS 10 5 1 Rated Versus Actual Current Draw of Equipment...

Страница 4: ...start up currents from large inductive loads could shut down the inverter Three major features are incorporated in SST First gradual voltage ramp upduring inverter start up This eliminates failed col...

Страница 5: ...t converts the high voltage DC into 110 volts 60 Hz AC The DC to DC converter stage uses modern high frequency power conversion techniques that have replaced the bulky transformers found in less techn...

Страница 6: ...voltage under the assumption that the waveform measured will be a pure sine wave These meters will not read the RMS voltage of a modified sine wave correctly They will read about 20 to 30 volts low wh...

Страница 7: ...volt DC plug firmly into the 12 volt DC socket of a vehicle or other DC power source CAUTION Connect directly to power source when operating above 175 watts NOTE Most automobile 12 volt DC circuits us...

Страница 8: ...he positive terminal of the DC source battery 4 Connect a length of wire on one side of the fuse holder or circuit breaker Connect the other end if the wire to the positive terminal of the inverter 5...

Страница 9: ...o not use the inverter to recharge items that q can be plugged directly into an AC receptacle This problem does not occur with the majority of battery operated equipment Most of these devices use a se...

Страница 10: ...nverter can be manually restarted by reseting the on off switch Resistive loads are the easiest for the MAXX 400 SST to run However larger resistive loads such as electric stoves or heaters usually re...

Страница 11: ...SST monitors the following potentially hazardous conditions LOW BATTERY VOLTAGE This condition is not harmful to the inverter but could damage the power source An audible alarm will sound when input...

Страница 12: ...emit a buzzing sound from their speakers when operated from the MAXX 400 SST power inverter This occurs because the power supply in the electronic device does not adequately filter the modified sine w...

Страница 13: ...alarm Bad connection or wiring Tighten all DC sounds continuously connections Low battery Low battery voltage Recharge battery alarm sounds Remove load from inverter while recharging battery Motorize...

Страница 14: ...You may also contact us by visiting our website www vectormfg com 10 SPECIFICATIONS Output Connection Dual North American Standard Receptacles Output Voltage Approx 110 volt AC RMS 60 Hz Output Curre...

Страница 15: ...oes not cover accessories bulbs fuses and batteries defects resulting from normal wear and tear including chips scratches abrasions discoloration or fading due to usage or exposure to sunlight acciden...

Страница 16: ...2004 VECTOR MANUFACTURING Ltd FT LAUDERDALE FL 33312 MADE IN CHINA VECTOR MANUFACTURING LTD...

Отзывы: