background image

14

Table III

Inflatables

Type

Pressure

Approximate Time

Car tire

185/70R14

30 psi

5 Min

Mid Size SUV 

235/70R16

30 psi

14 Min

Large Size SUV* 

265/70R17

42 psi

20 Min

Bicycle Tire 

26 X 1.25

95 psi

1 Min

Basketball 

5 “

10 psi

30 Seconds

Air Mattress** 

Twin

30 psi

30 Min

* Inflating time may vary due to degree of equipment deflation and unit’s battery charge

level.

** When inflating time exceeds 20 minutes, let unit rest after 15 minutes of continous use.

Let unit rest for 15 minutes, before continuing.

8. REPLACEMENT PARTS

For replacement parts (bulbs, batteries, fuses, etc.), contact Vector Customer Service:

(954) 584-4446 or toll-free (866) 584-5504.

8.1 BATTERY REPLACEMENT

It is recommended that the unit be returned to Vector Customer Service for

battery replacement: Contact (954) 584-4446 or toll-free (866) 584-5504.

WARNING:
• Do not dispose of the battery in fire as this may result in an explosion
• Before disposing of the battery, protect exposed terminals with heavy-duty

electrical tape to prevent shorting (shorting can result in injury or fire)

• Do not expose battery to fire or intense heat as it may explode

8.2 BATTERY DISPOSAL:

This unit contains a maintenance-free, non-spillable, sealed lead-

acid battery.  This battery is fully recyclable and should be accepted

at any location that accepts common automotive starter batteries.

Examples of places that accept these batteries are: County or

municipal recycling drop-off centers, scrap metal dealers and

retailers who sell automotive replacement lead acid starter

batteries. For more information on recycling this battery, call toll-

free (877) 288-7722.

9. SPECIFICATIONS

Model ................................................................................VEC022DSCC
Boost Ampere  ......................................450 Instantaneous Cranking Amps
Battery Type  ..................................................................Sealed, lead-acid, 

........................................

rechargeable, maintenance-free, 12 volt DC

Area Light  .................................... Cold Cathode Fluorescent Lamp (CCFL)
Booster Cables ........................................................Heavy Duty Cable with 

....................................................................

450 Amp Copper Clamps

Accessory Outlet   ........................................Self-Resetting Breaker 5 Amps
DC Charging Adapter  ..............................................................12 Volt DC
AC Charging Adapter ........110/120 Volt AC (700mA, 12 Volt DC Output)
Reverse Polarity Detection  ......................................................2 Volts (min)

Содержание START-IT VEC022DSCC

Страница 1: ...MATION YOU SHOULD KNOW Jump start any engine system with a standard 12 Volt DC battery Easy to read series of LED charge indicators Jump Start System can be recharged from any standard 110 120 Volt AC...

Страница 2: ...Fuse 11 4 4 Estimated Battery Life 11 5 OPERATING AS A PORTABLE POWER SUPPLY 11 6 EMERGENCY AREA LIGHT 12 7 COMPRESSOR TIRE INFLATOR 12 7 1 Warnings for Compressor Use 13 7 2 Tire Inflation or Product...

Страница 3: ...sion 9 When using this unit in proximity to the vehicle s battery and engine stand the unit on a flat stable surface and be sure to keep all clamps cords clothing and body parts away from moving vehic...

Страница 4: ...5 amps 5 This system is designed to be used only on vehicles with 12 Volt DC battery systems Do not connect to a 6 Volt or 24 Volt battery system 6 This system is not designed to be used as a replace...

Страница 5: ...ART SYSTEM to Jump start any engine system with a standard 12 Volt DC battery boat truck car airplane RV personal watercraft snowmobile garden tractor gasoline engine generator etc Operate 12 Volt DC...

Страница 6: ...ose Tire Chuck 6 Positive Red Clamp 7 INFLATOR Push Button 8 FAULT LED Indicator 9 ALARM LED Indicator 10 Display 11 Display ON OFF Push Button 12 LED Indicator 13 System Check Push Button 14 Alternat...

Страница 7: ...button will light the LCD display Pressing ON OFF will turn the unit s display on and off LIGHT turns the area light ON and OFF CHARGE LEVEL displays the internal battery percentage of the jumpstarte...

Страница 8: ...water 9 Do not wear vinyl clothing when jump starting a vehicle friction can cause dangerous static electricity sparks Remove all jewelry or metal objects they can cause short circuits or react with...

Страница 9: ...ct negative black clamp to chassis or a solid non moving metal vehicle component or body part Never clamp directly to negative battery terminal or moving part 5 Procedure for jump starting POSITIVE GR...

Страница 10: ...ion occurs seek immediate medical attention EYES If battery acid comes in contact with eyes flush eyes immediately for a minimum of 15 minutes and SEEK IMMEDIATE MEDICAL ATTENTION 4 CHARGING RECHARGIN...

Страница 11: ...ring DC charging disconnect DC adapter from accessory outlet push unit s ON OFF button to activate the display then push Charge Level button 4 DO NOT EXCEED 3 4 HOURS MAXIMUM 5 When charging is comple...

Страница 12: ...e area light s operating life is 100 000 hours 7 AIR COMPRESSOR TIRE INFLATOR IMPORTANT Read Instructions Carefully To Avoid Possible Injury or Property Damage The built in 12 Volt DC air compressor i...

Страница 13: ...res use of one of the adapters nozzles 1 Open the hatch and remove the nozzles noting their storage positions 2 Insert appropriate adapter e g needle into connector chuck and close thumb latch 3 Refer...

Страница 14: ...tery protect exposed terminals with heavy duty electrical tape to prevent shorting shorting can result in injury or fire Do not expose battery to fire or intense heat as it may explode 8 2 BATTERY DIS...

Отзывы: