background image

5

APPLIANCE POWER CONSUMPTION

MAXX SST

inverters are ideal for powering:

• Lights
• TVs and TV/DVD (VCR) combinations units
• Radio receivers/transceivers and stereo systems
• Computers and peripheral equipment
• Refrigerator/freezers
• Small microwave ovens
• Household appliances
• Dry and/or wet/dry vacuums
• Heavy duty power tools & chargers
• Sump pumps, motors and other electric-powered equipment

Most electrical tools, appliances and audio/video equipment have labels that show
the unit’s power consumption in amps, watts, or both. To avoid inverter shutdown and
possible damage to the inverter, avoid exceeding the wattage rating of this unit. To
obtain a rough estimate of the current (in amperes) the power source must deliver
where the power consumption of the tool or device is given in watts AC, simply divide
the power consumption of the load by 10.
Example: If a load is rated at 200 watts AC, the power source must be able to deliver:
200 divided by 10 = 20 amperes.
The inverter has built-in overload protection so that if you do exceed the inverter’s
output capacity continuously, the unit will automatically shut down. Once the
excessive load is removed, the inverter can be restarted and resume normal
operation.

Note:

To restart the inverter, turn it OFF, and then ON again. The ON/OFF Switch is
located on the unit’s Front Panel (see page 2).

The inverter powers resistive loads the easiest; however, larger resistive loads, such
as electric stoves or heaters, could draw more wattage than the inverter can deliver
on a continuous basis.

CAUTIONS

Ensure that total continuous power consumption of all tools and/or
appliances connected to the inverter (and in use) does not exceed the
inverter’s continuous watts rating. Also ensure that start-up wattage
for inductive loads does not exceed peak watts for more than a
second.
Appliances such as microwave ovens will normally draw more than
their rated current and could possibly overload the inverter when
operating simultaneously with other appliances.  For example:  A 600
watt microwave oven draws approximately 940 watts.

PRINCIPLE OF OPERATION

The MAXX SST

inverter converts 12 volt DC (direct current) from a vehicle battery or

other 12 volt DC power source to standard 120 volt AC (alternating current)
household power.
It converts power in two stages (see the diagram below). In the first stage, the inverter
raises the 12 volt DC input to 145 volts DC. This MAXX SST

inverter uses high-

frequency conversion techniques that replace bulky and heavy transformers found in
older inverters. In the second (output) stage, the inverter converts the 145 volt DC to
110/120 volt AC using multiple banks of metal-oxide semiconductor field-effect
transistors (MOSFETs). The unit’s solid-state circuitry ensures excellent overload
protection and the ability to operate reactive loads such as those found in inductive
motors. In this stage, the inverter functions as a high-power bipolar switch, alternately
applying opposite polarity to the AC outlet HOT and NEUTRAL terminals.

Notes:

Simplified diagram.
Cables, fuse and battery are not included and must be supplied by user.

The Power Inverter Output Waveform

The AC output waveform of the Power Inverter is known as “modified sine wave.” It
is a waveform that has characteristics similar to the sine wave shape of utility power.
This type of waveform is suitable for most AC loads, including linear and switching
power supplies used in electronic equipment, transformers, and motors.
The modified sine wave produced by the Power Inverter has an RMS (root mean
square) voltage of 115 volts, which is the same as standard household power. Most
AC voltmeters (both digital and analog) are sensitive to the average value of the
waveform rather than the RMS value. They are calibrated for RMS voltage under the
assumption that the waveform measured will be a pure sine wave. These meters will
not read the RMS voltage of a modified sine wave correctly. They will read about 20
to 30 volts low when measuring the output of the inverter. For accurate measurement
of the output voltage of this unit, use a true RMS reading voltmeter such as a Fluke
179, Fluke 79 III series, Beckman 4410 or Triplett 4200.

Modified Sine Wave and Sine Wave Comparison

SINE WAVE

MODIFIED

SINE WAVE

12 VOLT DC

INPUT FROM

BATTERY

AWG

WIRE

AWG

WIRE

AWG

WIRE

+ –

+

ANL

FUSE

(external)

TERMINAL

BLOCK

DC TO DC

CONVERTER

INTERNAL WARNINGS &

PROTECTION CIRCUITS

VOLT, AMP METERS

*

OVER TEMP &

VOLT INDICATORS

ON/OFF

SWITCH

145 VDC

MOSFET

BIPOLAR

SWITCH

BANKS

NEUTRAL

HOT

(2, 3 OR 4)

OUTLETS

GROUND

SENSE

FAULT

See Specifications on

page 16 for wire

gauges and fuse

amperages.

4

VEC049_thru_56D_Manual_092205  10/21/05  11:50 AM  Page 4

Содержание MAXX SST VEC056D

Страница 1: ...USER S MANUAL WARRANTY INFORMATION IMPORTANT SAFETY INFORMATION SAVE THESE INSTRUCTIONS VEC049D VEC053D VEC050D VEC054D VEC056D VEC051D MAXX SST Compact Power Inverters Converts 12 Volt DC to 120 Vol...

Страница 2: ...that cable insulation is not damaged Do not use with positive ground electrical systems Reverse polarity connection will result in a blown fuse and may cause permanent damage to the inverter and will...

Страница 3: ...ses that exceed those of other mobile installations Therefore the installer operator should be especially aware of the requirements to maintain secure tight water resistant electrical connections and...

Страница 4: ...shipping charges on all returned items During the warranty period manufacturer will be responsible for the return shipping charges to the customer in the United States LIMITATIONS This warranty does...

Страница 5: ...carefully before use to ensure optimum performance and to avoid damage to this product This Power Inverter is configured with the latest Soft Start Technology SST and supplies continuous power and pe...

Страница 6: ...Diagram Back View Diagram WATTAGE POWER METER ON OFF POWER SWITCH 2 120 VOLT AC OUTLETS RED FAULT LED INDICATOR HIGH SPEED COOLING FAN NEGATIVE TERMINALS GROUNDNG TERMINAL POSITIVE TERMINAL GREEN POWE...

Страница 7: ...DC MAXX SST uses a 12 volt DC power source like those found in motor vehicles or it can be operated using multiple battery configurations with commercial battery NEGATIVE TERMINALS GROUNDING TERMINAL...

Страница 8: ...wer Inverter Output Waveform The AC output waveform of the Power Inverter is known as modified sine wave It is a waveform that has characteristics similar to the sine wave shape of utility power This...

Страница 9: ...ction so that if you do exceed the inverter s output capacity continuously the unit will automatically shut down Once the excessive load is removed the inverter can be restarted and resume normal oper...

Страница 10: ...Cup Coffee Maker 5 5 605 Electric Trimmer 5 5 605 1 2 Hammer Drill 5 5 605 Reciprocating Saw 6 660 Vacuum Cleaner 7 2 792 1 1 8 Rotary Hammer 7 8 858 1 6 H P Submersible Sump Pump 8 880 Compact Microw...

Страница 11: ...he battery from being completely discharged The inverter will also shut down if the input voltage exceeds 15 5 volts This protects the inverter against excessive input voltage Although the inverter ha...

Страница 12: ...operate from the inverter To do this read the labels on the equipment to be operated 2 Estimate the number of hours the equipment will be in use between battery recharges 3 Determine the total watt ho...

Страница 13: ...city Protective Features LOW BATTERY ALARM An audible alarm will sound when the 12 volt DC power supply voltage drops down to 10 5 0 3 volts This indicates that the battery needs to be charged or ther...

Страница 14: ...and 105 F 40 C 3 At least three inches of clearance from other objects is maintained for cooling airflow 4 The unit is not exposed to direct heat sunlight or to explosive or flammable fumes and 5 The...

Страница 15: ...responding positive and negative terminals on the 12 volt DC vehicle battery or other 12 volt DC power source There may be some minor sparking 5 Turn the inverter ON OFF Switch ON 6 Plug in a lamp wit...

Страница 16: ...med the above preliminary installation steps proceed with the actual inverter installation Contact the manufacturer for any further installation information or questions You can purchase fuses fuse ho...

Страница 17: ...f after following all of the above steps the inverter does not perform properly the source voltage may be too low or the cables may be too long or the gauge too light Having checked and if necessary c...

Страница 18: ...rs The inverter ON OFF Switch must be in the OFF position when connecting the Remote Control to the unit or the Remote Control will not operate Once the unit has been turned ON using the Remote Contro...

Страница 19: ...hat high quality shielded antenna cable is used Do not use the inverter to operate high power appliances or tools at the same time you are using it to operate the TV Make sure the inverter s case is p...

Страница 20: ...15 5 0 Low Voltage Alarm 10 5 0 3 volts DC 10 5 0 3 volts DC 10 5 0 3 volts DC 10 5 0 3 volts DC 10 5 0 Low Voltage Shutdown 10 0 0 3 volts DC 10 0 0 3 volts DC 10 0 0 3 volts DC 10 0 0 3 volts DC 10...

Отзывы: