• A special moisture barrier, a conformal coating, that protects the internal circuit
board from failing from excess humidity conditions.
• Ground Fault Circuit Interrupt outlets
• Installation instructions especially geared for marine applications.
Built-in Safety Features include:
• Automatic overload and over-temperature shutdown and manual reset
• Automatic AC short-circuit shutdown and manual reset
• Automatic Ground Fault Circuit Interruption and manual reset
• Automatic low voltage audible alarm and reset (sounds when input drops below
10.6 volts DC)
• Automatic low-voltage shutdown and manual reset (activates when input drops
below 10.0 volts DC)
• Automatic high-input voltage shutdown (activates when input exceeds 15.5 volts
DC) and manual reset
• Moisture resistant
• Vibration resistant
Control and Function Guide
On the front panel are three LED indicators. The green Power LED indicates power
and proper operation of the inverter; the red Fault LED indicates inverter shutdown
from over-load or over-temperature condition; and the amber High Input LED indicates
inverter shutdown from abnormally high input voltages. The ON/OFF Switch turns the
inverter ON and OFF. The switch can also be used to force reset of inverter circuits
by switching it OFF, then back ON again.
120 volt AC power is supplied through Ground-Fault Circuit Interrupt (GFCI) North
American, household-type outlets. The VEC049GM and VEC050GM feature two
outlets; the VEC051GM features four. The outlets can accommodate either two- or
three-pin AC plugs.
VEC049GM Functions and Controls
Front View
Back View
ON/OFF
POWER
SWITCH
(2) 120 VOLT AC
GFCI OUTLETS
HIGH-SPEED
COOLING FANS
TERMINAL
COVER
RED FAULT
LED INDICATOR
GREEN POWER
LED INDICATOR
AMBER INPUT
FAULT LED
INDICATOR
NEGATIVE (–)
TERMINAL
POSITIVE (+)
TERMINAL
3
Maxx SST™ Portside Power Inverter Safety Features
Built-in Automatic Safety Features include:
• Overload and over-temperature shutdown activated if AC output exceeds rated watts
• AC short-circuit shutdown
• Low voltage audible alarm (sounds when input drops below 10.6 volts DC)
• Low-voltage shutdown (activates when input drops below 10.0 volts DC)
• High-input voltage shutdown (activates when input exceeds 15.5 volts DC)
MAXX SST
™
uses a 12 volt DC power source like those found in motor vehicles, or it
can be operated using multiple battery configurations with commercial battery
TERMINAL
COVERS
RED FAULT
LED INDICATOR
GREEN POWER
LED INDICATOR
AMBER INPUT
FAULT LED
INDICATOR
NEGATIVE (–)
TERMINAL
POSITIVE (+)
TERMINAL
VEC051GM Functions and Controls
Front View
Back View
(4) 120 VOLT AC
GFCI OUTLETS
BREAKERS
HIGH-SPEED
COOLING FAN
ON/OFF
POWER
SWITCH
VEC050GM Functions and Controls
Front View
Back View
ON/OFF
POWER
SWITCH
(2) 120 VOLT AC
GFCI OUTLETS
HIGH-SPEED
COOLING FANS
TERMINAL
COVER
RED FAULT
LED INDICATOR
GREEN POWER
LED INDICATOR
AMBER INPUT
FAULT LED
INDICATOR
NEGATIVE (–)
TERMINAL
POSITIVE (+)
TERMINAL