background image

11

ALWAYS RECYCLE

PRBA

PRBA

WARNING

• Do not dispose of the battery in fire as this may result in an explosion

• Before disposing of the battery, protect exposed terminals with heavy-duty 

electrical tape to prevent shorting (shorting can result in injury or fire)

• Do not expose battery to fire or intense heat as it may explode

Battery Disposal:

This unit contains a maintenance-free, non-spillable, sealed

lead-acid battery.  This battery is fully recyclable and should be

accepted at any location that accepts common automotive

starter batteries.  Examples of places that accept these batteries

are: County or municipal recycling drop-off centers, scrap metal

dealers and retailers who sell automotive replacement lead acid

starter batteries. For more information on recycling

this battery,

call toll-free (877) 288-7722.

12 Volt DC

Power Source

Figure 2 - Jump ‘n Charge Controls and Indicators

Reverse Connection Light

Good Connection Light

Battery

Level Status

PUSH Button

Four Battery

Level Status

LEDs

JUMP ‘N CHARGE CONTROLS AND INDICATORS

Figure 2 shows the Jump ‘n Charge system control panel, and consists of:

• Four Battery Level Status LEDs indicating Low to High levels of battery level status 
• Battery Level Status (PUSH) button lights LEDs above.
• Good Connection Light indicates a good clamp and terminal connection.
• Reverse Connection Light indicates the clamps are reversed.
• 12 Volt DC Power Source Outlet for use with 12 volt DC appliances and recharge

from vehicle battery

Содержание Jump 'n Charge VEC12B

Страница 1: ...04 IF YOU SHOULD EXPERIENCE A PROBLEM WITH YOUR VECTOR PURCHASE CALL TOLL FREE 866 584 5504 IN MOST CASES A VECTOR SERVICE REPRESENTATIVE CAN RESOLVE YOUR PROBLEM OVER THE PHONE BEFORE RETURNING THIS...

Страница 2: ...e to property 2 Use of an attachment not recommended or sold by the battery charger manufacturer may result in a risk of fire electric shock or injury to per sons and will void warranty 3 To reduce ri...

Страница 3: ...may cause explosion 6 Remove personal metal items such as rings bracelets necklaces and watches when working with a lead acid battery A lead acid battery can produce a short circuit current high enoug...

Страница 4: ...level can be viewed when the charge status pushbutton is pressed A 12 volt DC power accessory outlet is provided for use with appli ances that can operate from a vehicle 12 volt DC accessory outlet T...

Страница 5: ...nsfer 3 Stage Three Top Off Charge voltage is automatically maintained and reduced to a predetermined level while current is adjusted for a safe effective 100 battery charge step down regulation mode...

Страница 6: ...ery being charged gases from battery will corrode and damage charger 3 NEVER allow battery acid to drip on charger when reading specific gravity or fill ing battery 4 NEVER operate charger in a closed...

Страница 7: ...ns as follows ensuring a good con nection if there is a mistake the Reverse Polarity Indicator will light NEGATIVE GROUNDED VEHICLE Connect the POSITIVE RED charger clamp to the POSI TIVE POS P batter...

Страница 8: ...mp button selects the desired charge rate The selected Charge Rate is indicated by a lit vertical LED bar Once clamps are connected AC is connected and there is no reverse polarity condi tion press th...

Страница 9: ...ge time by 10 to ensure full charge In most cases battery charge times will vary depending on age and condi tion of battery Smaller batteries should be charged at the lower rate 2 Amps and add an extr...

Страница 10: ...LED will light If FAULT LED light comes on we recommend that you take your battery to a cer tified automotive service center for evaluation BATTERY NOT ACCEPTING A CHARGE Make sure that the charger i...

Страница 11: ...fully charged FUL will be displayed NOTE Small 12 volt DC batteries such as those used in motorcycles garden tractors ATVs jet skis and snowmobiles can be damaged by high charge rates ALWAYS select t...

Страница 12: ...centers scrap metal dealers and retailers who sell automotive replacement lead acid starter batteries For more information on recycling this battery call toll free 877 288 7722 12 Volt DC Power Sourc...

Страница 13: ...ving metal vehicle component or body part Never clamp directly to negative battery terminal or moving part If the audible alarm sounds the polarity is not correct Reverse the connections 4 Procedure f...

Страница 14: ...rate IMPORTANT Make sure all switches are turned off during recharging Recharge unit fully after each use WARNING Do not recharge for more than 3 4 hours maximum using 12 volt DC method OPERATION FOR...

Страница 15: ...t 15 14 Power tools bilge pump 24 10 Car vacuum 80 2 NOTE All times are approximate and based upon a fully charged unit EMERGENCY AREA LIGHT The Area Light is controlled by an ON OFF switch Make sure...