1. INTRODUCTION

Your new Vector MAXX SST™ 175 inverter is one in a series of the most

advanced DC to AC inverters available today. With proper care and

appropriate usage, it will give you years of dependable service in your car,

truck, RV or boat.

The inverter supplies 175 watts of continuous power, with a 350 watt peak,

in the form of one household-type receptacle that is ready to deliver

110/120VAC power whenever and wherever you need it! The heavy-duty

inverter has enough power to run almost any household or electronic

appliance, including color TVs (up to 20"), TV/VCR combinations, laptop

computers, camcorders, cellular phones, camcorders, power tool chargers,

lamps and many more. Added safety features include automatic shutdown

and a low battery alarm to prevent damage to your battery.

This power inverter is configured with the latest soft start technology (SST™)

to improve inverter operation. Before introduction of soft-start, high start-up

currents from large inductive loads could shut down the inverter. Three

major features are incorporated in SST™. First, gradual voltage ramp-up

during inverter start-up. This eliminates failed cold starts under load.

Second, output that momentarily dips in voltage and quickly recovers to allow

large motorized loads to start. This eliminates most shutdowns from momentary

overloads. Last, the inverter automatically re-starts when an overload that

caused inverter shutdown is removed. Previously, manual reset was required.

2. CONTROLS, INDICATORS AND CONNECTORS

FIGURE 1 details the front panel of the inverter. The front panel provides

two LED indicators. A green LED shows proper operation when lit. The red

LED shows inverter shutdown from overload, over voltage or over

temperature. Power is supplied through one grounded standard North

American outlet. The outlet accommodates either two or three pin AC

plugs. An ON/OFF switch turns the inverter circuitry ON and OFF.

The switch is used to force reset of inverter circuits if it is switched OFF,

then ON.

FIGURE 1

The backpanel (not shown) provides the DC power cord equipped with a

fused 12VDC plug.

1. RED SHUT DOWN LED

2. GREEN OPERATING LED

3. ONE 110/120VAC RECEPTACLE

4. ON/OFF SWITCH

3. HOW YOUR VECTOR INVERTER WORKS

The inverter converts low voltage DC (direct current) from a battery or other

power source to standard 110/120VAC (alternating current) household

power.

3.1 THEORY OF OPERATION

The inverter converts power in two stages. The first stage is a DC-to-DC

conversion process that raises the low voltage DC at the inverter input to

145VDC. The second stage, the actual inverter stage converts the high

voltage DC into 110/120VAC, 60 Hz AC. (See FIGURE 2).

The DC-to-DC converter stage uses modern high frequency power

conversion techniques that have replaced the bulky transformers found in

less technologically-advanced models. The inverter stage uses advanced

power MOSFET transistors in a full bridge configuration.

FIGURE 2 -

Theory of Operation

3.2 THE MAXX SST™ 175 OUTPUT WAVEFORM

The AC output waveform of the inverter is known as “modified sine wave”.

It is a waveform that has characteristics similar to the sine wave shape. This

type of waveform is suitable for most AC loads, including linear and

switching power supplies used in electronic equipment, transformers, and

motors. (See FIGURE 3).

The modified sine wave produced by the MAXX 175 inverter has an RMS

(root mean square) voltage of 110/120VAC, which is the same as

standard household power. Most AC voltmeters (both digital and analog)

are sensitive to the average value of the waveform rather than the RMS

value. They are calibrated for RMS voltage under the assumption that the

waveform measured will be a pure sine wave. These meters will not read

the RMS voltage of a modified sine wave correctly. They will read about 20

to 30 volts low when measuring the output of the inverter. For accurate

measurement of the output voltage of this unit, use a true RMS reading

voltmeter such as a Fluke 87, Fluke 8060A, Fluke 77/99 series, Beckman

4410, or Triplett 4200.

12VDC TO  

145VDC  

CONVERSION

145VDC TO 

110/120VAC 

CONVERSION

Internal  

Fuses

ONE AC  

Outlet

12VDC 

Input

110/120VAC, 60Hz 
To AC Appliances

4

3

2

1

4

5

Содержание Industrial Series VEC023

Страница 1: ...NG SAFETY OPERATION MAINTENANCE AND STORAGE OF THIS PRODUCT BEFORE USE READ AND UNDERSTAND ALL CAUTIONS WARNINGS INSTRUCTIONS AND PRODUCT LABELS PLUS YOUR VEHICLE S BATTERY MANUFACTURER GUIDELINES FAI...

Страница 2: ...als remain powered with respect to the ground terminals 3 DO NOT make any electrical connections or disconnections in areas designated as IGNITION PROTECTED This includes DC accessoryoutlettype connec...

Страница 3: ...ched OFF then ON FIGURE 1 The backpanel not shown provides the DC power cord equipped with a fused 12VDC plug 1 RED SHUT DOWN LED 2 GREEN OPERATING LED 3 ONE 110 120VAC RECEPTACLE 4 ON OFF SWITCH 3 HO...

Страница 4: ...se connectors may cause overheated wires and melted insulation Damage due to reversed polarity is not covered by our warranty 4 3 CONNECTION TO LOAD The inverter is equipped with a standard North Amer...

Страница 5: ...liances or equipment that produce heat such as hair dryers microwave ovens and toasters 5 2 BATTERY OPERATING TIME With a typical vehicle battery a minimum operating time of 2 to 3 hours can be expect...

Страница 6: ...le from the television the antenna and the antenna cables Use an extension cable if necessary Adjust the orientation of the inverter the antenna cables and the TV power cord to minimize interference M...

Страница 7: ...h h he e e ed d d d b b b by y y y c c c ca a a al l l ll l l li i i in n n ng g g g 9 9 9 95 5 5 54 4 4 4 5 5 5 58 8 8 84 4 4 4 4 4 4 44 4 4 44 4 4 46 6 6 6 o o o or r r r t t t to o o ol l l ll l l...

Страница 8: ......