5.1 Troubleshooting
◆
Before arc welding machines are dispatched from the factory, they have already been
debugged accurately. So forbid anyone who is not authorized by us to do any change to
the equipment!
◆
Maintenance course must be operated carefully. If any wire becomes flexible or is
misplaced, it maybe potential danger to user!
◆
Only professional maintenance personal who is authorized by us could overhaul the
machine!
◆
Guarantee to shut off the arc welding machine’s power before turn on the outline of
the equipment!
◆
If there is any problem and has no the authorized professional maintenance personal,
please contact local agent or the branch company!
If there are some simple troubles of welding machine, you can consult the following
overhauling chart:
Nr.
1
2
3
4
5
Troubles
Solution
Fan is broken
The power board is broken
The power cable is broken
There is something in the fan
The start capacitor of fan damaged
Turn on the power
source, power
indicator is lit, fan
is not working.
Turn on the
power source,
fan is working,
power indicator
is not lit
Turn on the power
source, fan is not
working ,power
indicator is not lit
Turn on the power
source, power
indicator is lit, fan
is working, there
is no welding
output.
The number of the
display is not
intact
Reasons
Change fan
Clean it
Change capacitor
The power light damaged or
connection is not good
The power cable connected not
good
Control board is broken
s t
1 inverter circuit damaged
n d
2 feedback circuit is fault
Digital tube is broken
The display panel is damaged
Change the display panel
Display panel is broken
The light of the power indicator is
broken and the problems
mentioned in Nr. 2
Change the light of the power
indicator or refer to the solution
in Nr. 2
Change it
Change it
Change it
Change it
Repair or change it
Change the power light
Connect correctly
Power on switch is damaged
The power board is broken
Change it
Replace it
Change it
Change it
6
No no-load
voltage output
(MMA)
If the overheat indicator is on
The main circuit is broken
The machine is broken
Wait a few minutes, the machine
can be operated normal
Check and repair
Consult the dealer or the
manufacturer
Troubleshooting
AC/DC WIG SERIES EQUIPMENT
Nr.
7
8
9
10
11
Troubles
Solution
The welding cable is not connected
with the two output if the welder
Connect the welding cable to
the welder's output
The welding cable is damaged
The earth cable connected unstably
The welding cable is too long
Input voltage not stable
There is oil or dust on the workpiece
Gas cylinder is close or gas
pressure is low
The HF igniting board does not work
Something is in the valve
Check if the function selected MMA Change the function to TIG
Check the HF funtion is selected
Select the HF funtion
HF board is broken
Earth clamp connect not stable
Repair or change it
Check the earth clamp
Open or change the gas cylinder
Remove it
Remove it
Change it
Change it
Change it
The distance between discharger is
too short or too long
The malfunction of the welding gun
switch
No argon gas flow or the air tube
connect not good
No argon gas flow or the air tube
connect not good
Pressure too high or air regulator is
broken
There is no Argon flow or the
connection is poor
The distance between tungsten
electrode and workpiece is too long
Repair or change it
Check the earth cable
Use an appropriate welding cable
Check the power supply
Check and remove it
Reduce the distance
(about 3mm ,less than 5mm)
Check and reconnect
Repair or change it
Adjust the distance (about 0.8mm)
Check the welding torch switch,
control cable and aero socket.
Check and reconnect
Check and reconnect
Check gas
Arc can not be
ignited (TIG) ,
there is spark
on the HF
igniting board
Arc can not be
ignited (TIG) ,
there is no spark
on the HF
igniting board
Turn on the
power source,
everything is
normal , but no
HF igniting
No gas flow (TIG)
Gas always flows
Reasons
Electromagnetic valve is damaged
Air tube is brocken
Something is in the valve
Electromagnetic valve is damaged
12
Checking if the electorde stick to
the work piece that the anti-stick
function is on
Repair or change it
The welding
current cannot
be adjusted
Control board is broken
Shut off the power when changing the torch
Separate the electrode and
work piece
Troubleshooting
AC/DC WIG SERIES EQUIPMENT