1.
Press the sliding key in the direction indicated by the arrow
and install the sensor (red-ended connection marker
There are red dot terminals, blue ends connecting blue dot
terminals)
。
2.
Plug in the power supply and turn on the power switch
。
②
Test the temperature of the tip
1.
Turn the °F/°C transfer switch to the appropriate position.
(°F: shows Fahrenheit temperature, °C: shows Celsius
temperature).
2. Toggle the selector switch toward the "TEMP" file.
3. Soldering iron tip, coated
with new solder
。
4. Quickly place the tip on the
test point of the temperature
sensor
*If you need to test the
temperature with an external
K-type sensor, you need to
insert the K-type sensor plug
into the external K-sensor
socket on the left side of the
soldering iron tester (the sensor on the terminal of the temperature
measurement zone must be removed.
5. The displayed value is constantly increasing, wait a few seconds,
and then read it after the value stabilizes.
③
Measure the voltage difference between the tip and ground
4
烙铁
测试点