Installation
IT IS IMPORTANT THESE INSTRUCTIONS ARE
READ FULLY BEFORE INSTALLATION
•
This product should not be used for any purpose other
than that for which it was designed and as shown
in this leaflet
•
All packaging should be removed and the unit checked
for damage in transit. If there is any damage, please
contact your supplier
•
The WHHR125DC- Aera will be installed vertically, and
generally be fitted into a cupboard, loft or ceiling void.
•
In order to comply with Construction (Design &
Management) Regulations, sufficient access for safe
maintenance (recommended on an annual basis), or
removal following installation, MUST be provided for
this product. See dimensions diagram.
•
Regulations and current Building Regulations. In order
to comply with these, it may be necessary to fit fire
dampers or other similar devices.
•
Flue gases from fuel-burning equipment must not
be drawn into a living area. If any room from which
air is extracted contains a fuel burning appliance,
such as a central heating boiler, then its flue must
be of the sealed or balanced flue type, or allowance
must be made for an adequate supply of air into the
room.
•
The unit must
NOT
be installed:
-
where there is excessive oil or grease
-
where there are hazardous gasses, liquids or
vapours that are flammable or corrosive
-
in ambient temperatures above 40ºC or lower than
0ºC
-
in areas of excessive humidity or in a wet
environment
•
Where possible the unit should
NO
T be installed
directly above a bedroom or living room.
•
The condensation drain
MUST
be fitted
•
Care should be taken to ensure that ducting is free from blockages
•
External grilles should be located a minimum of 600mm from any flue outlet in accordance with all
Regulations
•
The unit must be connected to a 230v, 50Hz single phase electrical supply fused at 3A.
• A triple pole isolation switch with contact separation of at least 3mm must be used to connect the appliance
to the fixed wiring when using the Switched Live.
•
The product should only be connected to the mains electricity supply or electrical outlet if:
- your electrical voltage and frequency correspond to those shown on the rating label.
- the capacity of your electricity supply is sufficiently powerful to operate the product at its
maximum power.
•
If one of the spigots is not connected to ducting a safety grille
MUST
be fitted to that spigot, so that it is
impossible for any moving part to be touched.
Installation of the appliance
MUST
be carried out by a qualified and suitably competent person and should be
carried out in clean, dry conditions where dust and humidity are at minimal levels. The unit is not suitable for
installation to the exterior of the dwelling.
Page 3
Incoming
fresh air
Cooled
outgoing
stale air
Fresh
air out
Stale
air in