"WHHR Midi" - WHOLE HOUSE HEAT RECOVERY UNIT
INSTALLATION AND OpERATINg & MAINTENANCE INSTRUCTIONS

Safety Notice

It is important to read this Instruction Manual carefully before installing or using the product.  Following
these instructions will ensure that your ventilation system is installed, commissioned and used properly and
continues to operate effectively.  Vectaire will not be held responsible and will not accept liability for any dam-
age caused to persons or property through failure to follow the guidance provided in this manual.   It should
always be available with the product for easy reference.

WHHR - Midi:

5"/125mm spigot, for dwellings up to 230m

2

, max capacity 102 litre/sec

general Information

The Vectaire WHHR Midi heat recovery system provides whole house
mechanical ventilation to living areas, bedrooms, kitchen and bathrooms.
It extracts stale, contaminated air from kitchens, utility rooms and bath-
rooms, and uses the heat recovered from this air to warm fresh, incom-
ing air to create a flow of fresh, filtered air throughout the dwelling.  The
extract and intake air streams are separated to avoid contamination.

The system will operate continuously to create a stable, comfortable,
healthy environment avoiding the use of excessive energy and saving
heat already generated.

The heat recovery unit must be installed vertically, and will generally be
sited in a cupboard.  It will be connected by hidden ductwork to vents
sited in the ceilings of the rooms which are to be ventilated.  Each unit
is commissioned individually so that the amount of air moved is tailored
to suit the performance required.  There will be a facility to boost the
extraction rate when desired (e.g when cooking or bathing, or when pol-
lutant levels rise).  This may be done automatically or manually.  

The  system  is  designed  to  run  continuously  and  should  NOT  be
switched off except for maintenance or filter replacement.   It is important to follow the advice in this user
manual and correctly install and maintain the system to ensure a healthy and comfortable indoor environment. 

Features
•    SAp Q Eligible

whole house heat recovery units giving continuous ventilation in the kitchen and up to seven

     additional wet rooms (using rigid ducting)

    low noise levels

    variable choice low (trickle) speed and boost options for optimum setting at installation

    boost speed triggered by a switched live connection from:

     -    a light switch (if more than one light switch is used, 

each one must be a double pole switch)

     

-    DRH240 (dynamic remote humidistat)

     -    PIRFF (passive infra red)
     -    THM (thermostat)

     

-    a remote switch/pull cord  

•    Economical EC motor with electronic control plus:

    

Standard control features

:

     

>

   

variable adjustment 

- trickle and boost speeds set at installation for both motors independently

     >    boost setting

- with integral overrun timer adjustable up to 20 minutes 

 >

optional delay-on-timer -

boost speed does not operate if switched off within 2 minutes

     >   integral frost-stat -

proportionately reduces intake motor speed as temperature falls

    Factory Set Options

     > change of ductwork handing
     >   purge boost 

- for rapid air change

     > BMS connections

- for remote motor shut off

> integral humidistat 

- proportionately increases motor speeds with rising  humidity 

>   summer bypass 

- automatic bypass of heat exchanger in hot weather

•    

Installation MUST be carried out by suitably qualified personnel and MUST be in accordance with current IEE 

     regulations

Incoming

fresh air

Warmed

fresh air

Cooled

outgoing

stale air

Outgoing stale air

Содержание WHHR Midi

Страница 1: ...WHHR Midi Residential Whole House Heat Recovery Unit with Low Energy DC Motor Installation Operating and Maintenance Instructions...

Страница 2: ...facility to boost the extraction rate when desired e g when cooking or bathing or when pol lutant levels rise This may be done automatically or manually The system is designed to run continuously and...

Страница 3: ...bedroom or living room The condensation drain MUST be fitted Care should be taken to ensure that ducting is free from blockages External grilles should be located a minimum of 600mm from any flue out...

Страница 4: ...ting bracket as a template to mark the five fixing hole centres 2 Check fixings supplied which are for a solid wall are suitable for your installation For a different type of mounting surface ensure a...

Страница 5: ...dia pipe must be fitted to the pipe connection If any part of the condensate drain is in an unheated space it MUST be insu lated with the equivalent of at least 25mm of insulating material with a ther...

Страница 6: ...h OFF bathroom light switch off measure the airflow rate at the extract valve and compare this to the design value If there is a difference adjust the potentiometer MIN MOT2 on the con trol board and...

Страница 7: ...l h drainage 6 Switch on the boost light switch ON 7 Measure the airflow rate at the extract valve and compare this to the design value If there is a difference adjust the potentiometer MAX MOT1 8 Re...

Страница 8: ...strap fitted carefully pull out the heat exchanger Caution if this is done during cold weather the heat exchanger may contain water It is advisable to have a plastic bowl avail able to avoid spillage...

Отзывы: