parts list
1 x Vectaire WHHR Midi/Midi-Lite unit.
1 x Wall mounting bracket.
1 x Safety bracket.
1 x Installation, Operation & Maintenance
Instructions
Any parts shortages or faults must be reported to the
supplier immediately.
Installation - mounting
Duct and Duct Connections
(refer to design drawing)
•
4 x 125mm nominal diameter spigots are provided for
the connection of ducting. These are clearly marked
for correct connection of the supply and exhaust ducts.
NB. ductwork installer should mark the "as installed" tick box on the label on the top of the unit to show
whether it is left or right handed.
Page 4
1. Mark a horizontal line on the wall using a spirit level.
This line will be approximately 40mm below the loc-
ation of the top face of the unit when fitted (exclud-
ing duct ports). Use the mounting bracket as a
template to mark the five fixing hole centres.
2. Check fixings supplied, which are for a solid wall,
are suitable for your installation. For a different
type of mounting surface, ensure appropriate
fixings are used. Drill holes for fixings.
3. Fit wall plugs into drilled holes
4. Mount the fixing bracket to the wall ensuring the
interlocking side is at the top, as shown
5. Mount the unit by locating the bracket on the back
of the unit securely over the mounting bracket
6. Fix the lower safety bracket as shown. Screw and
plug supplied are for solid wall - check that this is
appropriate for your installation (see '2' above.)