Vectaire PPF9 Скачать руководство пользователя страница 3

Pre-inspection

•    Inspect the unit and electrical supply cord for any damage (damage must be repaired by a suitably 

     qualified and competent person).

•    Check all parts are supplied as shown.

Parts list

     1  x  Vectaire PPF9 fan unit
     1 x Filter Box
     1  x  Ceiling Valve
     Flexible Duct and Worm Drive Clips
     Plaster Board Fixings and Screws
     Attenuation Mounts
     Installation, Operation & Maintenance Instructions

Any parts shortages or faults must be reported to the supplier immediately.

Installation - for loft mounting

1.  To fix the filter box, firstly remove screw 'A' and open the box as shown. Attach the box to two wooden bat-

tens fixed between the trusses using the screws, washers and rubber mounts supplied. Close the box and
secure with screw 'A'.

2.  Attach the fan section to the filter box using the two screws and plastic washers located in the protruding

tabs on the filter box.

3. Attach the ducting to the fan unit, using worm drive clips.  (Use the minimum length of ducting necessary and

cut off any excess.)

4.  Attach the black reducer to ducting, using worm drive clips.
5.  Cut a circular hole in the ceiling (approx. 205mm dia).
6.  Separate the front section of the valve from the ceiling plate and fix the plate to the ceiling with the spigot pro-

truding through the hole.

7.  Push the valve into the ceiling plate.
8.  Fix the reducer onto the valve ceiling plate.
9. Connect to power supply and adjust the fan speed setting to the desired level

Wiring Instructions (for fan without heater)

Connect the fitted supply cable to a local isolating switch.

Cleaning and Maintenance

Before any maintenance or cleaning operation, disconnect the appliance from the mains power supply.

Maintenance should only be carried out by properly qualified personnel.
The fan blades should be periodically checked and cleaned as necessary, usually after every six months of contin-
uous operation.  Use a soft brush to remove any accumulation of dust on the blades.
During the normal cleaning operations, check the integrity of all appliance parts.
The filters can be cleaned using the soft brush attachment of a vacuum cleaner.

Note: 

the filters should be replaced every two years.  Replacements are available from Vectaire Ltd.