prOBLEM
pOssIBLE CaUsE
hOW tO sOLVE thE prOBLEM
The product is not
working
No power
check to see that the electrical connection has been
properly made and that there is an electricity supply
coming to the fan.
The fan blade is not
turning
Blade obstructed
check to see there is nothing blocking it
Page 4
DIMEnsIOns
CLEanIng anD MaIntEnanCE
1.
Before carrying out any maintenance or cleaning operations the mains electrical supply MUst be
disconnected
.
2.
CLEANING AND MAINTENANCE SHOULD BE CARRIED OUT BY A QUALIFIED PERSON
3.
Before attempting to remove the motor impeller assembly disconnect the cable by removing the
terminal block inside the control box.
4.
Loosen the screws (Fig.8) without taking them off.
5.
Rotate slightly and remove the motor-impeller assembly (Fig. 8).
6.
Clean the motor-impeller assembly either with a dry brush or a dry cloth.
7.
Electrical parts
cannot
be cleaned.
8.
Reassemble in the reverse order to above (Fig 9).
trOUBLE shOOtIng
InstaLLatIOn
Содержание Microbox 125/2DC
Страница 9: ...Page 5 1 7 6 5 4 3 2 8 9...