"EVO350" - WHOLE HOUSE HEAT RECOVERY UNIT
INSTALLATION AND OPERATING INSTRUCTIONS
Safety Notice
It is important to read this Instruction Manual carefully before installing or using the product. Following
these instructions will ensure that your ventilation system is installed, commissioned and used properly and
continues to operate effectively. Vectaire will not be held responsible and will not accept liability for any dam-
age caused to persons or property through failure to follow the guidance provided in this manual. It should
always be available with the product for easy reference.
-
General Information
The Vectaire EVO350 heat recovery system provides whole house
mechanical ventilation to living areas, bedrooms, kitchen and bathrooms.
It extracts stale, contaminated air from kitchens, utility rooms and bath-
rooms, and uses the heat recovered from this air to warm fresh,
incoming air to create a flow of fresh air throughout the dwelling. The
extract and intake air streams are separated to avoid contamination.
The system will operate continuously to create a stable, comfortable,
healthy environment avoiding the use of excessive energy and saving
heat already generated.
The heat recovery unit will generally be installed in the loft of a house or
the void above the ceiling in an apartment (but may be installed in a cup-
board) and will be connected by hidden ductwork to vents sited in the
ceilings of the rooms which require ventilation. Each unit is commis-
sioned individually allowing its performance to be tailored to suit the
performance required. There will be a facility to boost the extraction
rate when desired (e.g when cooking or bathing or pollutant levels rise).
This may be done automatically or manually.
The system is designed to run continuously and should NOT be switched off except for maintenance or filter
replacement. It is important to follow the advice in this user manual and correctly install and maintain the
system to ensure a healthy and comfortable indoor environment.
Features
• SAP PCDB Listed
whole house heat recovery units giving continuous ventilation in the kitchen and up to seven
additional wet rooms
•
low noise levels
•
variable choice low (trickle) speed and boost options for optimum setting at installation
•
boost speed can be triggered by a switched live connection from a variety of external devices including:
- PIRFF (passive infra red)
*
- DRH240 (dynamic remote humidistat)
*
- THM (thermostat)
*
- a light switch (if more than one light switch is used,
each one must be a double pole switch)
- a remote switch/pull cord
or via LCD control panel
• Economical EC motor with electronic control plus:
Standard control features
> Independent motor speed control
•
Each motor can be adjusted independently
•
Trickle, boost and purge speeds can be set at installation
> Adjustable over-run timer -
from 0-90 Minutes, factory set to 0 minutes
> Adjustable delay-on timer -
from 0-5 Minutes, factory set to 2 minutes
> Integral frost stat –
proportionally reduces intake motor speed as temperature falls
> BMS connections
– for remote motor shut off
•
Installation MUST be carried out by suitably qualified personnel and MUST be in accordance with current IEE
regulations