TRIMMER ADJUSTMENT

To adjust the humidistat and timer trimmers, remove the front cover
of the fan (Fig 2) to access the trimmers. 

The humidistat (HY) can be adjusted between 40% and 90% relative
humidity.  Turn clockwise to decrease sensitivity and set at a higher
level of relative humidity.

The timer (T) is adjustable between 0 and 30 minutes.  Turn the trim-
mer clockwise to increase the overrun time, or anti-clockwise to
decrease it.

MAINTENANCE

Before any maintenance or

cleaning operation, switch off

the fan and disconnect it from

the main power supply. The

front cover can be cleaned

with a dry cloth or soft brush

The fan must not come into

contact with any kind of liquid

or solvent.  If this should occur,

contact a qualified technician

before reassembling the fan.

NOTE: The motor does not

require lubrication as it is

maintenance free "sealed

for life" type.

DISMANTLING & RECYCLING

This product has been designed and constructed using high-quality materials and components that can be recycled or re-used. 

Vectaire Ltd, Lincoln Road, Cressex Business Park, High Wycombe, Buckinghamshire, HP12 3RH

Tel: +44 (0)1494 522333.  Fax: +44 (0)1494 522337.  

Email: [email protected]  Web:  www.vectaire.co.uk

Elegance 11.1 4-5F12209-

Rev.3

E & O.E

SELV Products

All SELV (safety extra low voltage) products must be

installed to conform to IEC 60364.

• Connection between the fan and the mains 

supply must be by means of a safety isolating 

trans former of the appropriate power rating

• The transformer should be connected to the 

mains supply via a double pole safety switch 

with a contact opening of at least 3mm

• The transformer will operate only one fan

• The transformer must 

not

be installed in

Zones 1 or 2, but 

should 

be installed as close

as possible to the fan within Zone 3

• The cable used to connect the transformer to 

the fan must have a section area of at least 

1.5mm

2

and a maximum length of 10m

• If the fan is a humidity control model, it must 

be installed using the transformer supplied for 

that product. 

Содержание ELEGANCE EL1003DT

Страница 1: ...Q Eligible 3 speed continuous running timer humidity control SELV low voltage for all domestic wet rooms for walls ceilings or windows IPX4 IPX7 ELEGANCE Low Carbon Fan with EC Motor Installation and...

Страница 2: ...killed people To dispose of the pack aging and the appliance at the end of its useful life refer to the recycling rules in force The use of any electrical product requires compli ance with some basic...

Страница 3: ...ct must not exhaust into ducts designed to evacuate fumes from combustion in stoves or other combustion powered devices RANGE Trickle Speed 1 8 lt sec 28 8 m h Trickle Speed 2 13 lt sec 46 8 m h EL100...

Страница 4: ...over run timer adjustable from 0 to 30 minutes has completed its cycle The boost speed can also be activated by as described for model EL1003DT EL1003HDTLV SELV 12v version of EL1003HDT 4 INSTALLATION...

Страница 5: ...5 6 7 9 8 10...

Страница 6: ...properly fixed See dia 8 If cable is to come through rear of fan fit rubber ring included 9 screw fan to wall 10 connect cable using cable clamp see dia 10 NB this fan is double insulated and does no...

Страница 7: ...pre set at the factory depending on the fan model you have The user can boost the fan speed to its maximum performance by using cord or remote switch N B When installing fans via a remote switch pullc...

Страница 8: ...has been designed and constructed using high quality materials and components that can be recycled or re used Vectaire Ltd Lincoln Road Cressex Business Park High Wycombe Buckinghamshire HP12 3RH Tel...

Отзывы: