Vectaire ELEGANCE EL1003 Скачать руководство пользователя страница 6

6

11

INSTALLATION

1.  check there is nothing missing in box 

2. remove front cover

3. drill hole in wall - 

allow extra width if using 

ducting - it is the installer's responsibility to

use the appropriate core cutter to obtain 

the correct hole diameter.

4. use fan assembly as template to mark

drill holes 

5. drill 4 x 6mm dia holes

6. fit wall plugs

7/8 decide whether to have cable access

from rear (recessed) or top (surface) of fan - 

if from top ensure that included grommet is 

properly fixed.  (See dia 8).  If cable is to come

through rear of fan, fit rubber ring (included) 

9.    screw fan to wall

10. connect cable using cable clamp - see dia 10.

NB this fan is double insulated and does not

need to be earthed

11. replace front cover

N.B  This fan is NOT suitable for use with a

Gravity Grille.  It should be installed using either

a Cowl or Fixed Grille.

IMPORTANT

If the fan is installed in a ceiling with a vertical duct

passing through an unheated space, a condensa-

tion trap 

MUST

be fitted.  Any ducting in an

unheated space should also be insulated according

to the latest Building Regulations recommenda-

tions in the Domestic Ventilation Compliance

Guide. 

Failure to do this could result in condensation

affecting the operation of the fan and cause dam-

age to the ceiling.

Additionally for ceiling installation the pull-cord

switch should be put in the "off" position and the

cord removed.  A remote switch will be necessary

for changing the fan speed - see wiring diagrams

on following page.

Отзывы: