![Vectaire ELEGANCE EL1003 Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/vectaire/elegance-el1003/elegance-el1003_installation-and-operating-instructions-manual_3734868006.webp)
6
11
INSTALLATION
1. check there is nothing missing in box
2. remove front cover
3. drill hole in wall -
allow extra width if using
ducting - it is the installer's responsibility to
use the appropriate core cutter to obtain
the correct hole diameter.
4. use fan assembly as template to mark
drill holes
5. drill 4 x 6mm dia holes
6. fit wall plugs
7/8 decide whether to have cable access
from rear (recessed) or top (surface) of fan -
if from top ensure that included grommet is
properly fixed. (See dia 8). If cable is to come
through rear of fan, fit rubber ring (included)
9. screw fan to wall
10. connect cable using cable clamp - see dia 10.
NB this fan is double insulated and does not
need to be earthed
11. replace front cover
N.B This fan is NOT suitable for use with a
Gravity Grille. It should be installed using either
a Cowl or Fixed Grille.
IMPORTANT
If the fan is installed in a ceiling with a vertical duct
passing through an unheated space, a condensa-
tion trap
MUST
be fitted. Any ducting in an
unheated space should also be insulated according
to the latest Building Regulations recommenda-
tions in the Domestic Ventilation Compliance
Guide.
Failure to do this could result in condensation
affecting the operation of the fan and cause dam-
age to the ceiling.
Additionally for ceiling installation the pull-cord
switch should be put in the "off" position and the
cord removed. A remote switch will be necessary
for changing the fan speed - see wiring diagrams
on following page.