background image

USER

Manual

USER

Manual

1.0.0 Edition  20200103

Intel

®

 Core™ i7/i5/i3 SoC IP67 Rugged Embedded System

Multiple Waterproof M12 Connectors, Fanless -30°C to 70°C

RES-1000

Содержание RES-1000 Series

Страница 1: ...USER Manual USER Manual 1 0 0 Edition 20200103 Intel Core i7 i5 i3 SoC IP67 Rugged Embedded System Multiple Waterproof M12 Connectors Fanless 30 C to 70 C RES 1000...

Страница 2: ...ii Version Date Page Description Remark 0 10 2019 12 30 All Preliminary Release 1 00 2020 1 3 All Official Release Record of Revision...

Страница 3: ...it is not installed and used in accordance with the instruction manual it may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause h...

Страница 4: ...3MHz RAM DDR4 8G Certified DDR4 8GB 2133MHz RAM DDR4 4G Certified DDR4 4GB 2133MHz RAM 2 5 SATA HDD Certified 2 5 SATA HDD 2 5 SATA SSD Certified 2 5 SATA SSD mSATA SSD Certified mSATA SSD IP67 Rated...

Страница 5: ...4 CHAPTER 2 GETTING TO KNOW YOUR RES 1000 5 2 1 Packing List 5 2 2 Front Panel I O Functions 6 2 3 Rear Panel I O and Functions 6 CHAPTER 3 SYSTEM SETUP 10 3 1 How to Use Your RES 1000 10 3 2 Mount Yo...

Страница 6: ...vi APPENDIX A Watchdog Function 37 APPENDIX B Software Functions 39 APPENDIX C RAID Functions 40 APPENDIX D Power Consumption 44...

Страница 7: ...g Power Efficient Performance for demanding workloads Featured with 2 independent rugged X coded M12 GigE LANs support iAMT 11 0 2 M12 COM RS 232 422 485 1 M12 2 port USB 2 0 1 IP67 waterproof DVI D c...

Страница 8: ...V to 36V DC Power Input M12 waterproof connector One stop customized Design and Manufacturing Services 1 3 Product Specification System Processor Intel Core i7 i5 i3 Celeron U series Processor Skylake...

Страница 9: ...rottling control when CPU overheats Software Support Microsoft Windows 10 Windows 8 1 Windows 7 Linux Fedora 19 Ubuntu 10 04 LTS or Linux Kernel 3 0 above Mechanical Dimensions WxDxH 250mm x 180mm x 4...

Страница 10: ...0U 15W 4M Up to 3 4 GHz Yes i5 6300U 15W 3M Up to 3 0 GHz Yes i3 6100U 15W 3M Up to 2 3 GHz Yes Celeron 3955U 15W 2M Up to 2 0 GHz Yes 1 5 Mechanical Dimensions A A Detail 2 1 75 0 2 95 75 0 2 95 25 0...

Страница 11: ...RES 1000 2 1 Packing List Item Description Qty 1 RES 1000 Rugged Embedded System 1 2 Driver User Manual DVD 1 3 Wall Mount Kit 2 4 PHILLIPS F 6 32 screws for wall mount kit 4 5 M12 to USB cable 2M Le...

Страница 12: ...stem Status Blue Power System power status on off HDD 2 2 2 HDD LED Indicator Orange HDD LED A hard disk LED If the LED is on it indicates that the system s storage is functional If it is off it indic...

Страница 13: ...N 4 LAN0_MDI_2P LAN1_MDI_2P 5 LAN0_MDI_4P LAN1_MDI_4P 6 LAN0_MDI_4N LAN1_MDI_4N 7 LAN0_MDI_3N LAN1_MDI_3N 8 LAN0_MDI_3P LAN1_MDI_3P 2 3 2 10 100 1000 Mbps Ethernet Port DVI LAN 1 LAN 2 USB 2 0 COM 2 C...

Страница 14: ...able supporting up to 480MB per second data rate The pin outs of USB2 0 are listed as follows 2 3 4 Serial Port COM 2 and COM 3 DVI LAN 1 LAN 2 USB 2 0 COM 2 COM 3 DC IN Serial port COM2and COM3 can b...

Страница 15: ...XD TXD DATA 3 TXD RXD RXD 4 DTR RXD RXD 5 DSR RTS 6 RTS RTS 7 CTS CTS 8 GND GND GND GND Pin No DC IN Pin No USB2 0 1 VIN 4 GND 2 VIN 5 NC 3 GND 2 3 5 DC JACK DVI LAN 1 LAN 2 USB 2 0 COM 2 COM 3 DC IN...

Страница 16: ...10 HARDWARE INSTALLATION Vecow RES 1000 User Manual SYSTEM SETUP 3 1 How to Use Your RES 1000 3 Step 1 Remove M12 cover Example DC IN Step 2 Confirm M12 connector pin defined 3 1 1 M12 A code X code...

Страница 17: ...11 HARDWARE INSTALLATION Step 3 Confirm wire Step 4 Turn wire connector Step 5 Locked...

Страница 18: ...12 HARDWARE INSTALLATION Vecow RES 1000 User Manual Step 2 Confirm DVI connector pin defined 3 1 2 DVI Step 3 Confirm wire Step 1 Remove DVI cover...

Страница 19: ...13 HARDWARE INSTALLATION Step 5 Locked Step 4 Turn wire connector...

Страница 20: ...E INSTALLATION Vecow RES 1000 User Manual 3 2 Mount Your RES 1000 Step 1 Fasten four PHILLIPS 6 32 screws 110 0 4 33 160 0 6 30 180 0 7 09 250 0 9 84 282 2 11 11 296 2 11 66 44 0 1 73 48 3 1 90 3 2 1...

Страница 21: ...15 HARDWARE INSTALLATION 75 0 2 95 75 0 2 95 3 2 2 VESA Mount 75x75 mm...

Страница 22: ...r Manual BIOS SETUP 4 4 1 Entering Setup BIOS provides an interface for users to check and change system configuration The BIOS setup program is accessed by pressing the Del key when POST display outp...

Страница 23: ...main menu displays BIOS version and system information There are two options on Main menu Figure 4 2 BIOS Main Menu System Date Set the Date Use Tab to switch between Date elements System Time Set the...

Страница 24: ...nced Menu 4 3 1 ACPI Setting Enable Hibernation Enables or disables system s ability to hibernate OS S4 Sleep State This option may be not effective with some OS ACPI Sleep State Select the highest AC...

Страница 25: ...led This option just controls the BIOS extension execution If enabled this requires additional firmware in the SPI device Figure 4 3 2 Intel AMT Settings 4 3 3 PCH FW Configuration ME Unconfig on RTC...

Страница 26: ...r IO Configuration Serial Port 1 Configuration Set parameters of serial port 1 COM 1 Serial Port 2 Configuration Set parameters of serial port 2 COM 2 Serial Port 3 Configuration Set parameters of ser...

Страница 27: ...em voltages status monitoring Console Redirection Console redirection enable or disable Console Redirection Settings The settings specify how the host computer and the remote computer which the user i...

Страница 28: ...cores to enable in each processor package Intel Virtualization Technology When enabled a VMM can utilize the additional hardware capabilities provided by Vanderpool Technology Hardware Prefetcher To...

Страница 29: ...ported Turbo Mode Turbo Mode CPU C state Enable or disable CPU C states Enhanced C states Enable disabled C1E When enabled CPU will switch to minimum speed when all cores enter C State Package C State...

Страница 30: ...ble or disable SATA Device SATA Mode Selection Determines how SATA controller s operate Software Feature Mask Configuration RAID OROM RST driver will refer to the SWFM configuration to enable or disab...

Страница 31: ...le UEFI Network Stack Ipv4 PXE Support Enable Ipv4 PXE Boot Support If disabled IPV4 PXE boot option will not be created Ipv6 PXE Support Enable Ipv6 PXE Boot Support If disabled IPV6 PXE boot option...

Страница 32: ...0 this option is useful when any RT code is executed above 1MB Option ROM Messages Set display mode for Option ROM INT19 Trap Response BIOS reaction on INT19 trapping by Option ROM IMMEDIATE execute t...

Страница 33: ...able UEFI Network Stack Legacy USB Support Enables Legacy USB support AUTO option disables legacy support if no USB devices are connected DISABLE option will keep USB devices available only for EFI ap...

Страница 34: ...pt transfers Device reset time out USB mass storage device Start Unit command time out Device power up delay Maximum time the device will take before it properly reports itself to the host controller...

Страница 35: ...48MB 4 4 1 System Agent SA Configuration Figure 4 4 1 USB Settings Graphics Turbo IMON Current Graphics turbo IMON current values supported 14 31 Skip Scaning of External Gfx Card If enable it will no...

Страница 36: ...ature please disable CSM Support DVMT Pre Allocated Select DVMT 5 0 Pre Allocated Fixed Graphics Memory size used by the Internal Graphics Device DVMT Total Gfx Mem Select DVMT5 0 Total Graphic Memory...

Страница 37: ...te Serial IRQ Mode Configure Serial IRQ Mode State After G3 Specify what state to go to when power is re applied after a power failure G3 state S0 State Always turn on the system when power source plu...

Страница 38: ...PCIe Slot with SIM Mini PCIe Slot with SIM Settings Mini PCIe mSATA Slot Mini PCIe mSATA Slot Settings BIOS Lock Enable disable the PCH BIOS lock enable BLE bit feature 4 4 6 BIOS Security Configurati...

Страница 39: ...LCD Panel Type Select LCD Panel Resolution 4 4 8 LVDS Configuration Figure 4 4 8 LVDS Panel Settings 4 5 Security Administrator Password Set Administrator Password User Password Set User Password Fig...

Страница 40: ...er Setting Hard Disk Passwords Discard or save changes option in setup does not have any impact on HDD when password is set or removed If the Set HDD User Password option is grayed out do power cycle...

Страница 41: ...NumLock State Select the keyboard NumLock state Quiet Boot Enables or disables Quiet Boot option Boot Option x Sets the system boot order New Boot Option Policy Controls the placement of newly detecte...

Страница 42: ...changes Discard Changes and Reset Reset system setup without saving any changes Save Changes Save changes done so far to any of the setup options Discard Changes Discard changes done so far to any of...

Страница 43: ...2 bat Win8_64 bat Installation for driver and guideline to Framework 3 5 distribution for sample Win10_32 bat and Win10_64 bat Installation for driver and installation to Framework 3 5 distribution fo...

Страница 44: ...Cancel WDT and counting Use after Write button action WDT setup text User setting WDT value unit second Use for Write button activate WDT counting text read only WDT counting by program timer after s...

Страница 45: ...se rule Return TRUE 1 Success FALSE 0 Fail Driver not exists or initial error version is too old or machine not match BOOL GetWDT DWORD WDT Get watchdog timer setup WDT watchdog timer setup Unit secon...

Страница 46: ...he system is featured with three SATA include two internal SATA 1 mSATA You can select one of SATA ports for OS installation We used internal SATA for Windows 10 OS installation as an example C 3 To I...

Страница 47: ...US support highlights chpsts imsm The RAID environment has been done if you completed the steps above C 5 To Insert SATA HDD for RAID 1 Please notice you can use three SATA ports for SATA storage devi...

Страница 48: ...ure of SATA device allocation You will find Volume_0000 in SATA device at BIOS menu To start Disk Management tool and select Initialize Disk Then add Logical Device for Windows access C 8 If One SATA...

Страница 49: ...NT RAID HDD There is a warning will pop up to ask you if the disk is not a member of original RAID volume If you press Rebuild it will replace the broken SATA HDD to the last one SATA HDD of RAID volu...

Страница 50: ...CHI HTS542580K9SA00 80G USB3 0 1 USB Flash Transcend 3 0 8GB USB3 0 2 USB Flash Transcend 3 0 8GB USB3 0 3 USB Flash Transcend 3 0 8GB USB3 0 4 USB Flash Transcend 3 0 8GB USB2 0 1 USB Flash ADATA 8GB...

Страница 51: ...ess 3 Run 100 CPU Usage Max Current Max Consumption Max Current Max Consumption Max Current Max Consumption i5 6300U 12V 0 335A 04 02W 0 854A 10 25W 2 091A 25 09W i5 6300U 24V 0 284A 06 82W 0 580A 13...

Страница 52: ...fications are subject to change without prior notice No part of this publication may be reproduced in any form or by any means electric photocopying or recording without prior authorization from the p...