4 ELECTRICAL CIRCUIT
4.5 - MULTIPLE INSTALLATION
The CABIN air-conditioner is particularly suggested for a multiple installation. A multiple installation has these
specific features:
- One only sea water pump supplies water to all units.
- Each unit must have its own setting of compressor starting delay ( see 4.6 ).
4.5.1 - PUMP CONNECTION IN A MULTIPLE SYSTEM - C 307
In order to run the same pump from several units, it is available as option a pump relay box. Each air-condi-
tioner is connected to the pump relay box. The mains supply to the pump relay box must be independent from
the air-conditioners and protected by an independent fuse. The pump supply will come in parallel from each
relay controlled by each air-conditioner.
PM
RB
A.C.POWE
R
UNIT 2
EB
DELAY 10 S
UNIT 1
EB
DELAY 5 S
DELAY 15 S
UNIT 3 - 6
EB
230V 50Hz 115V 60 Hz
2 COMP.
M4621
M66170
3 COMP.
M4622
M66175
4 COMP.
M4622A
M66180
5 COMP.
M4622B
- -
6 COMP.
M4622C
- -
A.C.POWE
R
CODICE N. GRUPPI FUSIBILE
M4621
M4621
M4621
M4621
M4621
2
3
4
5
6
5A
5A
5A
10A
10A
PART
N. UNITS
PUMP FUSE