SLI180-SLI240-SLI360
© 2022 VebaBox User Manual
6
5
Installation
The battery must be attached to the floor of the car. The preferred position is below the thermal unit.
6
Operation
The battery battery, connected to the mains, automatically charges the internal battery. The charging process is
automatic and the battery cannot be overcharged. At the same time, the mains voltage is available at the mains
output of the battery pack as a means of connecting the thermal units. In this way, only one cord is used to
connect the entire installation to the power outlet.
The battery power supply also has a 12V output, which must be connected to the thermal unit. The thermal unit
prioritises mains power, if available, so that the battery does not drain when the installation is connected to the
mains.
The battery power supply contains battery protection, so that the battery is disconnected when fully discharged.
To prolong the life of the battery, do not fully discharge it if you don't need to, and if possible, plug it into the
mains for charging.
The battery should be stored fully charged if it is not going to be used for an extended period of time. Every 6
months of storage, it should be fully charged.
6.1
Controls
Battery power has no user controls. The function is automatic and the main switch is not used - the fully
automatic charging is in progress while the power cord is plugged in.
The device includes a battery monitor, which displays the remaining capacity and the process of
charging/discharging. The backlight on the display flashes when the battery is consumed.
Battery monitor also serves as an alarm, it gives an audible warning when the battery is low.
The battery monitor is factory set to the internal battery capacity.