Installation
Mounting
Specifications
Maintenance
Overheating
1. The distances shown in the above sketch are minimum. Distances less than shown may cause fire.
2. The connection box must always be positioned upwards.
3. The heater must not be covered or tampered to avoid overheating, fire or electric shock.
No maintenance is required except a periodic functional test and cleaning.
The heater is thermally protected by an overheat cut-out with manual reset.
If the overheat cut-out has tripped, the following should be observed:
1. Only an authorised electrician may open the connection box lid.
2. The mains power must be turned off.
3. Investigate carefully the reason for activation of the cut-out.
4. When the fault has been eliminated, the cut-out can be reset.
5
1. The
heater series are approved for installation in dry, damp or wet rooms
where there is risk for fire or explosion.
2. The heater must be connected to the mains supply with a fixed installed round cable, which ensures that
the electrical protection class of the heater is retained.
3. An all phase breaker with a contact gap of at least 3mm must be included in the fixed installation.
4. The installation must be carried out by an authorised electrician.
5. The heater is S-marked, CE-marked, EMC-marked and designed in accordance with the following standards:
/ EN 61000-3-2
.
6. This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental
capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction
concerning use of the appliance by a person responsible for their safety. Children should be supervised to
ensure that they do not play with the appliance.
EA
but not in environments
EN 60335-1 / EN 60335-2-30
/ EN 61000-3-3 / EN 61000-6-2 / EN 61000-6-3
> 1800 mm
> 300 mm
> 300 mm
> 300 mm
> 1800 mm
> 2500 mm
> 2500 mm
W
H
D
A
B
> 1800 mm
> 300 mm
> 300 mm
> 1800 mm
Type
EA 6
EA 9
EA 14
EA 21
EA 30
Rated voltage
400V 3N~ 50Hz
400V 3N~ 50Hz
400V 3N~ 50Hz
400V 3N~ 50Hz
400V 3N~ 50Hz
Rated power
6 kW
9 kW
14 kW
21 kW
30 kW
Reduced power
3 kW
6 kW
7 kW
14 kW
20 kW
Rated current
8.7 A
13.0 A
20.3 A
30.4 A
43.5 A
A
157 mm
157 mm
220 mm
220 mm
220 mm
B
425 mm
425 mm
600 mm
600 mm
600 mm
W
390 mm
390 mm
555 mm
555 mm
555 mm
H
450 mm
450 mm
600 mm
600 mm
600 mm
D
270 mm
270 mm
375 mm
375 mm
465 mm
EA