Tips for measuring your temperature
LADY-COMP
®
will wake you up with a tone. To switch off the tone,
click the control button. To measure your temperature, just press any
button on the home screen. LADY-COMP
®
will be ready to measure
when the “Measurement” symbol starts to blink.
– Now place the sensor under your tongue and close your mouth.
– Measurement will take approx. 60 seconds. If no measurement
value can be determined after 3 minutes, the measurement will be
cancelled automatically.
– The display shows measurement values from 34.5 to 41.0°C.
– From 37.8°C upwards, the measurement value will alternate
with F for fever.
– Once the measurement is completed, you will hear a tone and
your current temperature will appear on the screen. It will also
show your fertility status for that day.
Measurement period
The measurement period is the time span in which
you may proceed to measure your basal body tempe-
rature every day. This time span is monitored by the
LADY-COMP
®
device. The measurement period is inde-
pendent of the alarm and is calculated based on the
time you took your measurement on the previous day
(-3/+3 hours). The measurement period extends over
6 hours and begins/ends three hours before and after
the last measurement time, if this point in time does
not coincide with the time you wake up the next day.
Tips for the measurement period:
- The measurement period is displayed in form of
a measurement symbol on the home screen.
- Within the measurement period, pressing any button
on the home screen will start the measuring process.
- We recommend using the LADY-COMP
®
alarm
to wake you.
- Should you wake up any time within the measurement
period, e.g. because you have to nurse your child, start
to measure your temperature.
- Should you get up after the measurement period is
over, skip that measurement.
- You may redefine the measurement period at any time
by resetting the alarm (e.g. on weekends or in case of
working nightshifts).
After measurement, you will possibly see
«M» = menstruation blinking.
– In case of «M» yes, confirm «M» with «up» yes.
– In case of «M» no, reject «M» with «down» no.
As soon as LADY-COMP
®
knows everything about your cycle, the
device will prompt you for «M» on days that «M» is expected.
– The prompting for «M» («M» blinking) starts two days prior to «M».
– Once «M» is over, LADY-COMP
®
will stop prompting for «M».
After three measurement-free days, the measurement period will be cleared again and
measurement will only be possible the day after, in conjunction with an activated alarm.
The measurement period will then again depend on the wake-up time (-3/+3 hours).
Please note:
Confirm «M» on at least three
successive days. If you have «M»
without being prompted by your
device, activate «M» as described.
Should you have erroneously
input «M», you may correct «M»
on the same day and three days
backwards.