background image

5

TECHNICAL DATA

UNDER 250 (230VAC)

Max. weight per wing

500 Kg

Max. width per wing

2,5 m

Motors power supply

230 V ± 10%, 50 Hz

Condenser

10 

µ

F

Motor current input

1.2 – 1.6 A

Motor power

200W

Overload cutout

135°C

Torque given

250 Nm

Operator weight

10 Kg

Noise level

< 30 dB

Protection rating

IP 67

Opening time 90°

16 sec.

Mechanical release for emergency manoeuvre

With toothed lever provided

Working temperature

-20° C / + 55° C

UNDER 250 (24VDC)

Max. weight per wing

500 Kg

Max. width per wing

2,5 m

Motors power supply

24VDC

Motor current input

2,7 A

Motor power

60W

Torque given

200 Nm

Operator weight

10 Kg

Noise level

< 30 dB

Protection rating

IP 67

Opening time 90°

16 sec.

Mechanical release for emergency manoeuvre

With toothed lever provided

Working temperature

-20° C / + 55° C

Содержание UNDER 250

Страница 1: ...MANUAL UNDERGROUND OPERATOR FOR SWINGING GATES AND DOORS WARNING Before installing thoroughly read this manual that is an integral part of the pack The CE mark conforms to European directive EEC 89 33...

Страница 2: ...CAL DATA 5 4 DIMENSIONS 6 5 TYPICAL CONNECTION AND CABLE SECTION 6 6 INSTALLATION 7 6 1 GATE WING OPENING ANGLE 7 6 2 BOX INSTALLATION PROCEDURE 8 6 3 ASSEMBLING THE OPERATOR AND LEVERS 9 6 4 FASTENIN...

Страница 3: ...following items 1 Underground operator 1 Foundation box 1 Lever kit for 90 opening 1 Release lever Optional accessories 1 Remote control 1 Tuned antenna 433 920 1 Pair of outdoor photocells 1 Flashing...

Страница 4: ...PICAL AUTOMATION AND NAMES OF COMPONENTS Optimal installation 1 Operators 2 Electronic control unit 3 External photocell Internal photocell optional 4 Flashing warning light 5 Key switch 6 Antenna 7 R...

Страница 5: ...ating IP 67 Opening time 90 16 sec Mechanical release for emergency manoeuvre With toothed lever provided Working temperature 20 C 55 C UNDER 250 24VDC Max weight per wing 500 Kg Max width per wing 2...

Страница 6: ...6 4 DIMENSIONS 5 TYPICAL CONNECTION AND CABLE SECTION 2 x 0 75 mm2 RX Photocell TX Photocell 3 x 1 5 mm2 4 x 0 75 mm2 2x0 75mm2 4 x 1 5 mm2 4 x 1 5 mm2 230V line...

Страница 7: ...t working order hangs well on its hinges and is suitably lubricated It must also comply with the safety standards in force in the country of installation 6 INSTALLATION Introductory note Dig a hole bi...

Страница 8: ...rt the sheath for laying the power cables and limit switch F1D Note while positioning the box keep in mind the minimum distance there must be between the pillar and the centre of rotation of the gate...

Страница 9: ...Place the operator in the box and fasten it with the nuts provided 6 3 2 Insert the ball in the pin located on the box and fit the gate anchorage lever L1 6 3 3 Insert the lever L3 onto the motor sha...

Страница 10: ...rews provided View 6 4 2 Position the gate wing and the lever L1 so that they are perfectly aligned and fasten them by welding or similar 6 5 EMERGENCY RELEASE PROCEDURE Insert the key CHS provided in...

Страница 11: ...the remote control recognition procedure on the radio receiver or replace the battery with a new one On giving a command the flashing warning light works slowly and the light is dim 2 A fuse blown Re...

Страница 12: ...ablished by the installer the manufacturer and by current legislation All installation maintenance repairs and cleaning operations must be documented This documentation must be preserved by the user a...

Страница 13: ...5 7550 216 7017 216 7018 Fax 218 5542 Mobil 30 940 1970 20 949 2688 1141 Budapest Fogarasi t 77 Tel 220 7940 220 7814 220 7959 220 8881 364 3428 Fax 220 7940 E mail delton delton hu Web www delton hu...

Отзывы: