Nuts
INSTALLATION WITH BASE PLATE (OPTIONAL)
Take the floor plate and bend the brackets as needed. Dig a suitably sized hole in
the ground.
Insert the electrical conduit into the cable conduit hole of the floor plate.
Level
and cement the floor plate.
INSTALLATION
Set up an electrical multi-duct conduit in the middle of the foundation of the barrier,
corresponding to the central hole (corrugated - diameter 25 - 50mm).
Place the barrier on the floor
plate and fasten it with the
self-locking M12 nuts supplied.
Brackets
Base plate
Cable conduit
hole
INSTALLATION WITHOUT BASE PLATE
Place the barrier and block it through the four holes present internally on the basis.
1
2
3
4
Fixing holes