ELECTRICAL CONNECTION

N.O. = Normally Open Contact

N.C. = Normally Closed Contact

1

Antenna

2

Start-stop-photocell common contact

1 mm²

3

Start contact N.O.

1 mm²

4

Photocell  contact N. C. (put a jumper if nor used)

1 mm²

5

Stop contact N. C. (put a jumper if nor used)

1 mm²

6

Limit switches common contact

1 mm²

7

Closure limit switch contact N.C. (put a jumper if nor used)

1 mm²

8

Opening  limit switch contact N.C. (put a jumper if nor used)

1 mm²

9

Accessory  power supply common

1 mm²

10

+ 12Vdc

 accessory power supply (photocells)

1 mm²

11-12

Flashing light free contact

1 mm²

13-14

Motor connection

24 Vdc

1 mm²

15

Encoder connection

Negative

1 mm²

16

Encoder connection

signal

1 mm²

17

Encoder connection

+5V

1 mm²

18-19

Power Input 24 Vac (

Transformer

)

1,5 mm²

LAY OUT

4

ON

8

RF CODE  CLOSE 

OPEN 

PROG

C

O

M

P

H

O

TO

S

T

A

R

T

A

N

T

S

T

O

P

C

O

M

F

C

C

F

C

A

C

O

M

+

1

2

V

LAMP

RELAY

 

MOTOR

  -

SIG  +5

  24Vac

1   2    3   4   5   6   7   8    9  10

 12

11

13

14

15

16

17

18

19

LED

5   6   7         8   9

1        2        3        4

LED

LED

10

LED

10

   

+

   

+

TR1

POWER

SLOW
SPEED

TR2

Содержание AT 7070

Страница 1: ...installing thoroughly read this manual that is an integral part of the pack The CE mark conforms to European directive EEC 89 336 92 31 93 68 D L 04 12 1992 N 476 Our products if installed by qualified personnel capable to evaluate risks comply with norms UNI EN 12453 EN 12445 ...

Страница 2: ... contact N C put a jumper if nor used 1 mm 9 Accessory power supply common 1 mm 10 12Vdc accessory power supply photocells 1 mm 11 12 Flashing light free contact 1 mm 13 14 Motor connection 24 Vdc 1 mm 15 Encoder connection Negative 1 mm 16 Encoder connection signal 1 mm 17 Encoder connection 5V 1 mm 18 19 Power Input 24 Vac Transformer 1 5 mm LAY OUT 1 2 3 4 ON 5 6 7 8 RF CODE CLOSE OPEN PROG COM...

Страница 3: ...ning or waiting for automatic closing It turns off after 30 seconds the operator stop SLOW START CLOSING The automation during closing start at slow speed The automation during closing start at normal speed OPERATOR RUNNING DIRECTION Normale polarity Reversed polarity 1 2 3 4 ON ON ON ON DIP 1 ON OFF LED MEANINGS TABLE N LED DESCRIPTION 1 RADIO 2 CLOSE 3 OPEN 4 PROGRAMMING 5 START N LED DESCRIPTIO...

Страница 4: ...immer toward to provide more strength to the operator and less sensibility to the intervention of the amperostop Increase trimmer toward to provide less strength to the operator and more sensibility to the intervention of the amperostop SLOWING DOWN ADJUSTMENT To adjust the slowing down speed Before programming stroke Ÿ Open the door with OPEN button and adjust trimmer TR2 to have the required spe...

Страница 5: ...olling code Ÿ PROGRAMMING Press RF CODE button LED lights for 10 seconds press the transmitter button you want to program programming is completed Ÿ DELETING CODES To delete all codes in memory hold RF CODE for 10 seconds until LED begins to blink the operation is completed WITH SLOW DOWN IN START CLOSING DIP SWITCH 7 ON WITHOUT SLOW DOWN IN START CLOSING DIP SWITCH 7 OFF Ÿ Press OPEN button bring...

Страница 6: ... AMPEROSTOP FUNCTION Opening Ÿ Blocking the movement of the door Closing Block ing and reverse in opening the movement of the door START COMMAND FUNCTION A START impluse by button or radio transmitter with closed door has the following function Ÿ STEP BY STEP OPEN STOP CLOSE STOP OPEN Ÿ AUTOMATIC OPEN STOP AUTOMATIC CLOSURE O CLOSURE WITH IMPULSE STOP OPEN ...

Страница 7: ......

Страница 8: ...e characteristics of the products described in its sole discretion without notice CONTACTS AUTOMAZIONE ACCESSI MADE IN ITALY Via Circolare p i p N 10 65010 Santa Teresa di Spoltore PE ITALY Tel 39 085 4971946 FAX 39 085 4973849 www vdsconsorzio it vds vdsconsorzio it Rev 2 02 14 ING ...

Отзывы: