vds AT 7070 Скачать руководство пользователя страница 1

Electronic control board for sectional door operator

AT 7070

WARNING!! Before installing, thoroughly read this manual that is an   integral

part of the pack

The  CE  mark  conforms  to  European  directive

EEC 89/336 + 92/31 + 93/68 D.L. 04/12/1992 N. 476.

Our products if installed by qualified personnel capable to evaluate risks,

comply with norms UNI EN 12453, EN 12445

Содержание AT 7070

Страница 1: ...installing thoroughly read this manual that is an integral part of the pack The CE mark conforms to European directive EEC 89 336 92 31 93 68 D L 04 12 1992 N 476 Our products if installed by qualified personnel capable to evaluate risks comply with norms UNI EN 12453 EN 12445 ...

Страница 2: ... contact N C put a jumper if nor used 1 mm 9 Accessory power supply common 1 mm 10 12Vdc accessory power supply photocells 1 mm 11 12 Flashing light free contact 1 mm 13 14 Motor connection 24 Vdc 1 mm 15 Encoder connection Negative 1 mm 16 Encoder connection signal 1 mm 17 Encoder connection 5V 1 mm 18 19 Power Input 24 Vac Transformer 1 5 mm LAY OUT 1 2 3 4 ON 5 6 7 8 RF CODE CLOSE OPEN PROG COM...

Страница 3: ...ning or waiting for automatic closing It turns off after 30 seconds the operator stop SLOW START CLOSING The automation during closing start at slow speed The automation during closing start at normal speed OPERATOR RUNNING DIRECTION Normale polarity Reversed polarity 1 2 3 4 ON ON ON ON DIP 1 ON OFF LED MEANINGS TABLE N LED DESCRIPTION 1 RADIO 2 CLOSE 3 OPEN 4 PROGRAMMING 5 START N LED DESCRIPTIO...

Страница 4: ...immer toward to provide more strength to the operator and less sensibility to the intervention of the amperostop Increase trimmer toward to provide less strength to the operator and more sensibility to the intervention of the amperostop SLOWING DOWN ADJUSTMENT To adjust the slowing down speed Before programming stroke Ÿ Open the door with OPEN button and adjust trimmer TR2 to have the required spe...

Страница 5: ...olling code Ÿ PROGRAMMING Press RF CODE button LED lights for 10 seconds press the transmitter button you want to program programming is completed Ÿ DELETING CODES To delete all codes in memory hold RF CODE for 10 seconds until LED begins to blink the operation is completed WITH SLOW DOWN IN START CLOSING DIP SWITCH 7 ON WITHOUT SLOW DOWN IN START CLOSING DIP SWITCH 7 OFF Ÿ Press OPEN button bring...

Страница 6: ... AMPEROSTOP FUNCTION Opening Ÿ Blocking the movement of the door Closing Block ing and reverse in opening the movement of the door START COMMAND FUNCTION A START impluse by button or radio transmitter with closed door has the following function Ÿ STEP BY STEP OPEN STOP CLOSE STOP OPEN Ÿ AUTOMATIC OPEN STOP AUTOMATIC CLOSURE O CLOSURE WITH IMPULSE STOP OPEN ...

Страница 7: ......

Страница 8: ...e characteristics of the products described in its sole discretion without notice CONTACTS AUTOMAZIONE ACCESSI MADE IN ITALY Via Circolare p i p N 10 65010 Santa Teresa di Spoltore PE ITALY Tel 39 085 4971946 FAX 39 085 4973849 www vdsconsorzio it vds vdsconsorzio it Rev 2 02 14 ING ...