background image

 

Viewline Hours Counter

 

 

Technische Änderungen vorbehalten

 12/09 

Technical details subject to change

 

2 - 3 

 

The reproduction, distribution and utilization of this document as well as the communication of its contents to others without express 
authorization is prohibited. Offenders will be held liable for the payment of damages. All right reserved in the event of the grant of a patent, 
utility model or design

 

 

Technical Data  

Installation depth 

50mm 

 
Operating Voltage  

9 – 30 Volt DC 

 
Accuracy  

+/- 5 Sec / d (at 14V DC, 23°C, NL45) 

 
Current consumption  

< 30 mA, at 12V (without Illumination) 

 
Operating temperature 

-40°C to +80°C; plated bezels (chrome) -40°C to +70°C 

 
Storage temperature 

-40°C to +85°C for 48h; plated bezels (chrome) -40°C to +70°C 

 
Temperature shock 

in Conformity to IEC 60068 – 2 -14 

 
Climatic test 

in Conformity to IEC 60068 – 2 -30 Db Variant 2 

 
EMC in conformity with 

DIN_EN 61000-6-2 

 DIN_EN 

61000-6-3 

 
Standards GL, 

Category 

C, 

F (under preparation) 

 
Vibration 

in Conformity to IEC 60068 – 2 – 6 

 

and DIN EN 60068 – 2 – 64 in combination with DIN EN 60068 – 2 - 14 

 
Mechanical shock 

in Conformity to IEC 60068 – 2 – 27 

 

and DIN EN 60068 – 2 – 29  

 
 
Chemical resistance against  - preservative agent 
 

- preservative agent remover 

 

- cold cleaner 

 

- methylated spirit 

 

- interior cleaner 

 

- drinks containing caffeine and tannin 

 
Nominal position 

NL 0 to NL 90 (DIN16257) 

 
Protection class  

according to IEC 60529 

 

Front: IP67 (in Nominal position) 

 

Rear: IP52 (in Nominal position) 

 
Reverse polarity protection  yes 
 
Over voltage protection 

yes, max 70 V for 250 ms 