4 Test procedure for the KITAS
Testing Instructions for CTC II
4.2 KITAS status message
4.2
KITAS status message
When KITAS pulse signal testing has been completed
successfully, the digital status of the KITAS sensor is read out
and displayed; see the following
Section entitled “KITAS
.
You can call up KITAS status messages without having to test
the KITAS. To do this, connect the CTC II to the power supply
and select
KITAS > Sensor test > KITAS status
.
◄
Important
1
The test device establishes the data interchange with the
KITAS.
The digital status of the KITAS sensor is displayed after
roughly 15 seconds.
2
You can see whether or not the KITAS signal (encrypted) is
being received via the KITAS sensor cable in the
Test
display.
•
Test successful
:
The KITAS signal is being received.
•
No initialisation
:
The KITAS signal is not being received.
# KITAS STATUS #
TEST SUCCESSFUL
KITAS = DTCO
CONTINUE WITH KEY