![background image](http://html.mh-extra.com/html/vdo/compass/compass_manual_858135015.webp)
- Compensation not possible.
- Remove magnetic disturbances
„
FAIL
“ is displayed, or the
near the sensor (cans, tools, etc.)
compensation cannot be
- Check cable connection between
concluded
indicating instrument and sensor
(bad connections ?)
- Wrong indication
- Run automatic compensation
- Adjust compass sensor correctly
- Set local variation
- Inclination fault (wrong
- Magnetic disturbances above or
indication with heeling ship)
below compass sensor
- Remove disturbances
- Select other location of sensor
- Display shows
- Connection indicator- sensor is
broken
- Sensor is broken
- Check cable connection between
indicating instrument and sensor
Maintenance of the VDO Compass
Indicating instrument and compass sensor are maintenance-free. Clean
the indicating instrument with a clean, humid or antistatic cloth.
The front lens is plastic. Do not use detergents to prevent scratches and
fisheyes.
34
MAINTENANCE