ON
DIP
ASSEMBLY INSTRUCTIONS
Technical details subject to change
TU00-0761-5507150
10/18
Warning point adjuster 2910002025200
TU00-0761-5507150
1–3
3
EN
6
For normal operation set switch 3 to ON
and switch 4 to OFF.
Selecting the warning range:
For the warning with increasing sensor resistance,
set switch 1 to ON and switch 2 to OFF.
Turn the potentiometer until the pointer is at the posi-
tion where the warning lamp is to be triggered. (During
the adjusting procedure itself, the warning lamp is not
triggered depending on the pointer position.)
Selecting the warning range:
For the warning with falling sensor resistance,
set switch 1 to OFF and switch 2 to ON.
Turn the potentiometer until the pointer is at the posi-
tion where the warning lamp is to be triggered. (During
the adjusting procedure itself, the warning lamp is not
triggered depending on the pointer position.)
Examples:
Level gauge with dip tube level sensor, warning if fill
level is too low (fuel).
Temperature indicator, warning if temperature is too
low (oil/water).
Pressure indicator, warning if pressure is too high (oil).
Examples:
Pressure indicator, warning if pressure is too low (oil).
Level gauge with lever level sensor,
warning if fill level is too low (fuel).
Example:
Temperature indicator, warning if temperature is too
high (oil, water).
8
7
Insert the main power switch again if necessary.
Switch the ignition on and carry out a functional test.
Re-programme other devices which may have lost your
saved settings.
1 2 3 4
ON
DIP
1 2 3 4
9
1 2 3 4
ON
DIP