*  Operation

 

The thermostat is operated using seven buttons on the front: 

ON/OFF

 

- switches the controller on and off with LED indicator 

SETP.

 

- select, view/change the setpoint value 

SENS.

 

- view the values from the individual temperature sensors 

PRG

 

- access to the internal parameters 

RESET ALARM

 

- reset button for resetting alarms with LED indicator 

UP

 

- increase the set value (setpoint/parameters) 

DOWN

 

- reduce the set value (setpoint/parameters)

 

 
 

*  Switching the controller on and off

 

The LED above the 

ON/OFF

 button shows whether the controller is on or off. 

Pressing the 

ON/OFF

 button (for at least 1 second) switches the controller on or off. If the thermostat is 

switched  off,  then  all  the  displays  are  blank  and  its  regulating  function  is  disabled.  If  the  thermostat  is 
switched  on,  the  room  temperature  is  usually  displayed  in  the  top  display  and  the  active  setpoint  in  the 
bottom display. If a controller delay has been defined after a power interruption then the time remaining is 
shown in the lower display (blinking). 

 
 

*  View the individual setpoints

 

In normal operating mode, the room temperature is shown in the top display (default). If necessary, this can 
be changed using parameter P80. 
 
The  LED

=

s  next  to  the 

SENS.

  Button  indicates  which  temperature  is  displayed  on  the  top  display: 

>

I

=

  = 

Sensor-1 (room temperature), 

>

II

=

 = Sensor-2 (channel temperature), 

>

I

=

 and 

>

II

=

 both on = average of Sensor 

1 and Sensor 2. The other temperatures (if present and used) can be displayed by now pressing the 

SENS

 

button one or more times. A blinking LED indicates that another temperature is being displayed as normal. 
 
A  few  seconds  after  releasing  the 

SENS.

  button  or  by  pressing  the 

ON/OFF

  button,  the  normal  room 

temperature (P80) will reappear in the display. 

 
 

*  View the individual setpoints

 

The LED

=

s next to the 

SETP.

 button indicate which setpoint is active. This is shown on the bottom display. 

The  other  setpoint  will  be  displayed  (if  set  using  P01)  by  pressing  the 

SETP.

  button.  A  blinking  LED 

indicates that the inactive setpoint is being displayed. 
 
A few seconds after releasing the 

SETP.

 button or by pressing the 

ON/OFF

 button, the active setpoint will 

reappear in the display and the corresponding LED will be illuminated continuously. 

 
 

*  Changing setpoints

 

Press  (if  necessary)  the 

SETP.

  button  until  the  desired  setpoint  appears  in  the  display  and  release  the 

SETP.

 button. The setpoint can now be changed by pressing the 

SETP

. button at the same time as the 

UP

 

or 

DOWN

 buttons. A few seconds after releasing the buttons or by pressing the 

ON/OFF

 button, the normal 

room temperature (P80) will reappear in the display. 

 
 

*  Mode display

 

The LED

=

s mode S and mode D next to the top display indicate the active mode of the controller. 

The LED 

  (Max. Limit) indicates whether a maximum limit is active. 

The LED

=

s Out-1, Out-2 and Out-3 show the relays that are active. 

 
 

*  Setting internal parameters

 

The functioning of the controller can be configured using the internal parameters. By pressing the 

PRG

 and 

DOWN

 buttons simultaneously, you can access the internal programming menu. A letter 

>

P

=

 followed by a 

number (= parameter number) will appear in the top display. The 

UP

 and/or 

DOWN

 buttons can be used to 

look up the desired parameter. 
The value of this parameter is shown in the lower display. This value can be adjusted by pressing the 

SETP

button at the same time as the 

UP

 or 

DOWN

 buttons. 

A few seconds after releasing the buttons or by pressing the 

ON/OFF

 button, the controller returns to the 

normal operating mode. 

Содержание MC 885-SDHL

Страница 1: ...d burner high as shown in the functional flow figure One of these control functions can be set for each relay If a burner has to be controlled with a change over relay contact burner high low control function burner high can be used for this on RY2 or RY3 The measurement and control range are both 50 to 300 C with a readout per 1 C The control range can be reduced using the parameter setting The t...

Страница 2: ... pressing the ON OFF button the normal room temperature P80 will reappear in the display View the individual setpoints The LED s next to the SETP button indicate which setpoint is active This is shown on the bottom display The other setpoint will be displayed if set using P01 by pressing the SETP button A blinking LED indicates that the inactive setpoint is being displayed A few seconds after rele...

Страница 3: ...rner low duty cycle for modulating control Burner low cycle time for modulating control Burner high differential Burner high offset Burner high only together with burner on 0 no 1 yes Burner high modulating control 0 no 1 yes Burner low duty cycle for modulating control Burner low cycle time for modulating control 0 1 15 50 50 0 1 15 50 50 0 1 0 to 1 0 100 5 240 0 1 15 50 50 0 1 0 1 0 100 5 240 0 ...

Страница 4: ...relative to control setpoint Maximum alarm detection during 0 Spraying 1 Drying 2 Both modes always detection for single setpoint Maximum alarm temperature Switch differential for maximum alarm Time delay for maximum alarm Action at minimum alarm message with code and alarm relay function always appear in display 0 None 1 Inhibit all burner control 2 Inhibit burner high 3 Inhibit burner high repla...

Страница 5: ...rameter will have to be reduced by 2 5 C Basic regulation function The basic control is set using parameters P01 04 P20 37 and P40 42 A single mode setpoint or 2 modes setpoints P01 Only a room temperature or a channel temperature sensor P02 Control temperature for mode S and for single mode P03 Control temperature for mode D P04 The basic control supports 3 adjustment functions Burner on burner l...

Страница 6: ... Functional flow ...

Страница 7: ...or circuit Maximum limit The basic control can be overruled by the maximum limit if set using parameters P70 P75 At which temperature P70 in which mode P71 with which differential P73 and time delay P74 the maximum limit should come into effect can be set using parameters The desired overruling action can be set using parameter P75 When the maximum limit is active this will be indicated by the LED...

Страница 8: ...e sensor option a b c 3 wire system Digital input Contact input function spray open dry closed Potential free connection Analogue output 0 10 Vdc or 0 5 Vdc P46 measurement or setpoint value output max 1mA Choice via parameter P45 Room temperature Channel temperature if present Lowest sensor temperature Highest sensor temperature Average sensor temperature Control temperature active sensor Spray s...

Страница 9: ... Wiring diagram ...

Страница 10: ... Dimensions Address VDH Products BV Tel 31 0 50 30 28 900 Produktieweg 1 Fax 31 0 50 30 28 980 9301 ZS Roden Email info vdhproducts nl The Netherlands Internet www vdhproducts nl ...

Отзывы: