VDH ALFA 75-MTT Скачать руководство пользователя страница 1

1

User manual
ALFA 75-MTT

MilkTankThermostat.

VDH doc. 080723

Version: v1.0

Date: 27-05-2008

Software: ALFA75-MTT

File: Do080723.WPD

Range: 0,0/+80,0

C pro 0,1

C

* Description.

The 

ALFA 75-MTT

 is a Milk tank thermostat with the next functions: 

- Cooling:

On adjusted set point (f.i. 4,0

C).

- Stir:

Continuos during cooling and on adjustable intervals when cooling is off.
Manuel stir after pushing the button on the front (with time limitation) 

- Temperature alarm: An alarm will be given when the adjusted minimum and maximum temperature values

are exceed.  The alarms are reported with an error code on the display, the buzzer will
be activated and the relay will be energized. A time delay can be adjusted for the alarms.

- Cooling time alarm:

When the temperature doesn’t reach the temperature set point within the adjusted time,
an alarm will be given (with buzzer and relay).

- Digital input:

If the digital input is closed during cleaning than the control will stop and the display will
only show the cleaning temperature.

* Installation.

On the connection diagram from the 

ALFA 75-MTT

 is shown how the sensor, supply and relays should be

connected. After power up a self test is started. If the self test is completed the display will show the measured
temperature.

* Control.

The 

ALFA 75-MTT

 can be controlled by four push buttons on the front:

(SET) 

- viewing / changing from the adjusted value and alarm reset.

(UP)

- raise the adjusted value.

(DOWN) 

- lower the adjusted value.

(STIR)

- Start stir manual.

* Normal operation.

During normal operation will the temperature from the temperature sensor be shown. Range 0,0 till 80,0 

C.

* Viewing the set point.

By pushing the 

SET

 key the set point appears in the display. The   led starts flashing to indicate this.

A few seconds after releasing the 

SET

 key the set point disappears  and the measured temperature

is shown again.

* Changing the set point.

Push the 

SET

 key and the set point appears on the display. Release the 

SET

 key. Push the 

SET

 key again

together with the 

UP

 or 

DOWN

 keys to change the set point. A few seconds after releasing the 

SET

 key the set

point disappears  and the measured temperature is shown again.

* Adjusting internal parameter.

Next to the adjustment of the set point, some internal settings can be made like differentials, sensor offset and
stir functions.
By pushing the 

DOWN

 key for more than 10 seconds, you enter the  'internal programming menu'. 

On the left display the upper and the lower segments are flashing. Over the 

UP

 and 

DOWN

 keys the required

parameter can be selected (see table for the parameters).
If the required parameter is selected, the value can be read-out by pushing the 

SET

 key. Pushing the 

UP

 and

DOWN

 keys allows you to change the value of this parameter.

If no key is pushed for 20 seconds, the 

ALFA 75-MTT

 changes to it’s normal operation mode.