![Vaxcel T0616 Скачать руководство пользователя страница 2](http://html1.mh-extra.com/html/vaxcel/t0616/t0616_assembly-and-installation-instructions_3726063002.webp)
Page 2 / 3
Illumination & CCT
:
At dask, the light turns to high-level brightness
(100%) a
t
CCT 5000K, and stays "ON" for 6 hours, then after 6
hours,
it turns to low-level brightness
(30%) a
t
CCT 5000K.
* When i
n "Low Level" mode,
turn the wall switch "OFF" then
"ON"
twice
within 3 seconds, the light
will then remain
o
n
at
full
brightness (5000K) all night long.
*
To shift back to "Low Level" mode,
turn the wall switch "OFF" then
turn
it "ON" twice within 3 seconds again.
*
The
will automatically
light turn off at dawn.
LOW LEVEL
Manual
Override
Manual Override Operation Diagram
Turn wall switch OFF-ON-OFF-ON
in 0.5~3 Seconds
Turn wall switch OFF-ON-OFF-ON
in 0.5~3 Seconds
Fig.5
Installation Steps
Turn off the power at fuse or circuit box.
Turn on the power at the main fuse or circuit breaker box.
Adjusting the Light Head:
Fig.4
1. The fixture mounting bracket is pre-assembled on the light fixture. Unscrew both the decorative cover and the fixture
mounting screw in order to remove the mounting bracket.
2. Install the mounting strap to the outlet box with the stamped word “FRONT” facing away from the outlet box, using two
mounting screws that best fit the outlet box. Mounting bracket should sit flush against wall surface when secured.
(Choose one matching pair of suitable mounting screws from the 3 pairs provided).
3.
Pull out the source wires from the outlet box. Using a 1/8” flat-head screwdriver connect the black wire from the outlet
box to the "L" interface of the terminal station on the mounting bracket. Connect the white wire from the outlet box to
the "N" interface of the terminal station on the mounting bracket. Connect the Ground wire from outlet box to "GND"
interface of the terminal station on the mounting bracket. Carefully tuck the wires back into the outlet box.
4. Place mounting bracket against the outlet box, insert the mounting bracket screw through the mounting bracket hole,
thread mounting bracket screw into the center hole of the mounting strap. Tighten the mounting bracket screw securely.
5.
Attach the backplate of the light fixture to the mounting fixture mounting screw. Then push the decorative cover firmly
into the fixture mounting screw hole on the light fixture. Tighten the fixture mounting screw securely.
6. With silicone caulking compound, caulk completely around where the back plate meets the wall surface.
CAUTION: Be sure to caulk completely where the back plate meets the wall surface to prevent water from
seeping into the outlet box.
22012
6
Manual Override (nighttime operation only)
:
Adjustable Joint
Both lamp heads can be adjusted to point towards
your desired light coverage area by turning and
bending the Adjustable Joint.
Keep the light heads at least 1˝ (25mm) away from
the sensor.(See Fig. 4)
1.
.
Keep the light heads 30˚ below horizontal to avoid
water damage and
electrical shock.
2.