FUNCTION AND OPERATION
Off Mode
Auto Mode
Manual
Override
Manual Override Operation Diagram
Turn wall switch OFF-ON
in 0.5~3 Seconds
Turn wall switch OFF-ON
in 0.5~3 Seconds
Fig. 4
Choose a mode by sliding the slide switch. The light will turn on immediately when power is applied. Wait for 30 seconds
to allow the sensor to warm up.
1. Test MODE (daytime and nighttime operation.)
• The light will turn to low-level brightness (0~50%).The light will turn to high-level brightness (full brightness) when
motion is detected, and stay on as long as the motion continues. The light will turn to the low-level brightness you
set after 5 seconds when motion is no longer detected.
2. Off MODE (nighttime operation only)
• At dusk, the light stays off and will turn to high-level brightness (full brightness) when motion is detected, and stay on
as long as the motion continues. When the motion stops, the light will stay on for the predetermined time set
(5 ~ 180 seconds), then the light will turn off automatically.
3. Auto MODE (nighttime operation only)
• At dusk, the light will turn to low-level brightness (0~50%). The light will turn to high-level brightness (full brightness)
when motion is detected, and stay on as long as the motion continues. When the motion stops, the light will remain
on for the predetermined time set (5~180 seconds), and then turn to the low-level brightness you set.
• The light will turn off automatically at dawn.
The light will turn on (full brightness) automatically at dusk and turn off automatically at dawn.
4. PC MODE (nighttime operation only)
•
5. Manual Override MODE (nighttime operation only)
• To shift to the manual override mode, set the switch to “Off” or “Auto”
mode. Turn the wall switch “OFF” and then turn it “ON” within 3
seconds. The light will stay on through all night. To restore to the
“Off” or “Auto” mode, turn the wall switch “OFF” and then turn it “ON”
within 3 seconds again. (See Fig.4)
• The light will last for one night only and turn off automatically at dawn.
Note: 1. The low level brightness can be adjusted from 0 to 50% by
rotating “Low level” knob. (See Fig.5)
2. Always keep the wall switch in the “ON” position (including the daytime).
3. Please notice the warm up time is 30 seconds, any operations are invalid during this time.
The Position of Control Panel
Sensor
Lens
Fig.1
Sensor
Lens
Fig.3
Fig.2
View Fig.A
Step 1: Rotate the sensor lens from left side to right side
to show the adjustable knobs and slide switch.
(See Fig.1)
Step 2: Adjust time low level brightness and sensitivity
by knobs and choose the mode you want by
slide switch. (See Fig.2 and Fig A).
Step 3: Restore the sensor lens to original position.
(See Fig.3)
“TIME” Knob
“LOW LEVEL” Knob
“SENS” Knob
Small Screwdriver
(not included)
Slide Switch
TEST
OFF
AUTO
PC
TIME
LOW LEVEL
SENS
Fig.A
Page 3 of 5
200313