Function and Operation

MODES OF OPERATION

Choose a mode by sliding the switch on the back of the sensor. when power is first applied, the light 

will turn on immediately. Wait for 100 seconds to allow the sensor to warm up. 

 1. TEST MODE (daytime and nighttime operation)

    ● The light will turn to low-level brightness (0%~50% brightness). The light will turn to high-level brightness (100%

        brightness) when motion is detected, and stay on as long as the motion is continuing. The light will revert to

        low-level brightness about 5 seconds after motion is no 

longer detected.

2. 3H MODE (nighttime operation only)

    ● At dusk, the light will turn to high-level brightness (100% brightness). The light will turn to low-level brightness (0%

       ~50% brightness) automatically after 3 hours. The light will turn to high-level brightness (100% brightness) when

       motion is detected, and stay on as long as the motion is continuing. When motion is no longer detected, the light

       will remain on for the predetermined time you set (5~18

0

 seconds), and then revert to low-level brightness you set.

    ● Light will turn off automatically at dawn, and return to 3 H

 mode at dusk.

3. 6H MODE (nighttime operation only)

    ● At dusk, the light will turn to high-level brightness (100% brightness). The light will turn to low-level brightness (0%

       ~50% brightness) automatically after 6 hours. The light will turn to high-level brightness (100% brightness) when

       motion is detected, and stay on as long as the motion is continuing. When motion is no longer detected, the light

       will remain on for the predetermined time you set (5~18

0

 seconds), and then revert to low-level brightness you set

    ● Light will turn off automatically at dawn, and return to 6 H

 mode at dusk.

4. 0 MODE (nighttime operation only)

    ● The light will turn to low level brightness (0%~50% brightness) at dusk. The light will turn to high-level brightness

       (100% brightness) when motion is detected, and stay o

n as long as the motion is continuing. When motion is no

       longer detected, the light will remain on for the predeterm

ined time you set (5~180 seconds), and then revert to

       low level brightness you set.

    ● Light will turn off automatically at dawn, and return to 0 H

 mode at dusk.

5.Manual Override MODE (nighttime operation only; on at d

usk,off at dawn)

  ● In 3, 6 or 0 mode, to shift to manual override mode, turn o

ff the wall switch in 3 seconds and then turn it on again,

     the light will turn to high-level brightness at dusk, and turn off automatically at dawn. To return to the previous

     settings, turn off the wall switch in 3 seconds and then turn it on again. (See Fig.1)

  ● The lights will turn off automatically at dawn.

 

Installation steps

 

1. 

Thread two headless screws through the cross bar, and then secure them with four lock nuts (two on each side of the 

     cross bar). 

Adjust the length of the headless screws if necessar

y.

     Note: Make sure that the headless screws are lined up hor

izontally to make the fixture level.

2. Attach cross bar to the outlet box using two mounting

 screws.

3. Pull out the source wires from the outlet box. Make wire connections using wire nuts as follows:   

    ---Connect the hot wire (usually black insulation) from the f

ixture to the black wire from the power source.

    ---Connect the neutral wire (usually white insulation) from t

he fixture to the white wire from the power source. 

    ---Attach the fixture grounding wire (usually green insulatio

n or bare wire) to the cross bar with the green 

        grounding screw, and then connect it to the house grounding wire with the wire nut.  

   Carefully put the wires back into the outlet box. 

4. Attach the fixture to the cross bar by inserting headless screws into holes on back plate, and then secure it with 

    two rubber pads and two ball nuts. 

    

NOTE

:

With silicone caulking compound, caulk completely around where the back plate meets with the wall 

surface to prevent water from seeping into the outlet box.

5. Install a bulb (not included). Check relamping label at socke

t area or packaging for maximum allowed wattage.

  

Turn off the power at fuse or circuit box.

   

Turn on the power at fuse or circuit box.