Function and Operation

Choose a mode by

 sliding the switch on the bottom of the sensor. 

 (See Fig.6)

Note: When power is first applied, the light will turn on to 100% brightness. The sensor will take 30 seconds 

to warm up.

1. Test mode (daytime or nighttime operation )

    ● Rotate the knob on the left side of the back plate to the “TEST” 

       position (See Fig.7)

    ● With the power on, the light turn

s to low-level brightness 

       automatically.

    ● The light turns to high-level brightness when motion is detected, 

        and stays on as long as the motion continues. Then it reverts back 

        to low-level brightness about 5 seconds after motion is no longer 

        detected.

 Note: You can adjust the low 

level brightness

 

(0~50%) 

by using 

 the 

low level brightness knob on the right side of the back plate

 (See Fig. 7)

2. AUTO MODE (nighttime operation only) 

    ● 

To shift to “AUTO” mode, rotate Time Delay knob arrow to point to 

        the desired time setting (between 5 seconds and 3 minutes). At 

        dusk, the light turns on to pre-selected low level brightness. When 

        motion is detected, the light turns to full brightness and stays on as

        long as motion continues. When the motion is no longer detected, 

        the light at full brightness remains on for the predetermined time you

        set (5s ~ 3min), and then switches back to low level automatically.

     ● The light turns off automatically at dawn.

    Note: You can adjust the low 

level brightness

 

(0~50%) 

by using 

    the 

low level brightness knob

(See Fig. 7)

Adjustment Sensor Lower For Short Coverage

Adjustment Sensor Higher For Long Coverage

Fig. 5

1. Gently grasp the light heads and tilt them up or down, left or right to 

    adjust the light coverage area. Keep the light heads at least 1˝ (25mm) 

    away from the sensor.(See Fig. 5)

2. 

Keep the light heads 30˚ below horizontal to avoid water damage and 

    electrical shock.

Fig. 3

Fig. 4

Adjusting the Light Head: 

Fig. 6

Fig. 7

Mode

Sensitivity

Delay Time

Low Level Brightness

Sensitivity of Motion Sensor 

     ●  You can adjust the sensitivity of the motion sensor by using the “SENSITIVITY” selector located on the right side 

          of the bottom surface of the sensor. (See Fig. 6)

     ●   Adjust motion sensor sensitivity to HIGH (H), MEDIUM (M), or LOW (L) to achieve desired performance.

     ●   Approximate range for each setting: 20 ft. (L), 45 ft. (M), 70 ft. (H).