Vaxcel T0193 Скачать руководство пользователя страница 3

160425

Page 3 / 4

 

CUSTOMIZATION OPTIONS:

Shut-off Delay

The Shut-off delay is the length of time the light will stay at high-

level brightness after motion has ceased to be detected. This 

Shut-off delay can be set when operation is in 3, 6 or 0 Mode by

using the “TIME” knob located on the left side of the panel at the

bottom of the back plate (See Fig.4) . To increase the shut-off 

delay, turn the knob clockwise. To decrease shut off delay, turn 

the knob counterclockwise. The delay may be adjusted from a minimum of 5 seconds to a maximum of 3 minutes. The

light will stay on as long as motion is detected continuously and will automatically turn to low-level brightness when no 

more motion is detected after the delay time has passed.   

Sensitivity of Motion Sensor

The sensitivity of the motion sensor can be adjusted by using the “SENSITIVITY” knob located on the right side of the 

panel at the bottom of the back plate (See Fig.4). To increase sensitivity, turn the knob clockwise. To decrease 

sensitivity, turn the knob counterclockwise. The sensitivity may be adjusted from a minimum of 5 feet to a maximum of 

35 feet.

NOTE:

1. The sensitivity of the motion sensor will increase as the

    environmental temperature gets cooler. For best 

    performance, gently clean the lens with a soft cloth every 

    1 or 2 months to assure maximum sensitivity.

2. For best performance, install fixture at least 6 feet above

    the ground. At such a height, the fixture will provide a

    detection distance of up to 35 feet at 77 degrees

    Fahrenheit. (See Fig.5)

3. The sensor detects across a detection range of 120 degrees.

    (See Fig.6)

4. The sensor will be more sensitive to motion across its 

    detection path than motion directly towards it. (See Fig.7)

5. To reduce possible nuisances, do not mount the fixture

    near a heat source like an air conditioner, vent or furnace 

    exhaust, or in a direction facing any reflecting object or 

    other light source.  

Motion

Least sensitive

Motion

Most sensitive

Sensor

(Adjustable low level)

 (View from one side of Back plate)

Fig.3

Fig.6

Fig.5

Fig.7

 

“3H Mode”

“6H Mode”

“0 Mode”

Manual

Override

Mode

Turn wall switch OFF-ON

in 3 Seconds

 

 

Turn wall switch OFF-ON

in 3 Seconds again 

Fig.2

Manual Override Operation Diagram

           (View from Bottom of Back plate)

(Exterior Wall)

TIME

                         SENSITIVITY

TEST

0

3 6

Fig.4

5.Manual Override MODE (nighttime operation only; on at dusk,off at dawn)

       ● In 3, 6 or 0 mode, to shift to manual override mode, turn off the wall switch in 3 seconds and then turn it on 

          again, the light will turn to high-level brightness at dusk, and turn off automatically at dawn. To return to the 

          previous settings, turn off the wall switch in 3 seconds and then turn it on again.  (See Fig.2)     

       ● The lights will turn off automatically at dawn. 

Note:You can adjust the low level brightness (0~50%) by using the slide switch on the side of back plate.

(See Fig.3) 

  

5'

8.0'

6.5'

35'

Where you install your lantern is important:

Be sure the light is mounted straight on the wall; 

otherwise, the detection distance may be limited.

120°

Содержание T0193

Страница 1: ...hut off power at the main fuse or circuit breaker box Be aware that simply turning off the wall switch is not sufficient to prevent an electrical shock 4 This fixture requires a 120V AC 60 Hz power source 5 Do not attempt to take the lantern apart there are no serviceable parts inside 6 To avoid sensor damage by lightning or electrical surge make sure the grounding wire is securely connected 7 For...

Страница 2: ...r is first applied the light will turn to high level brightness wait for 15 seconds to allow the sensor to warm up 1 TEST MODE daytime and nighttime operation The light will turn to low level brightness 0 50 brightness The light will turn to high level brightness 100 brightness when motion is detected and stay on as long as the motion is continuing The light will revert to low level brightness abo...

Страница 3: ...the ground At such a height the fixture will provide a detection distance of up to 35 feet at 77 degrees Fahrenheit See Fig 5 3 The sensor detects across a detection range of 120 degrees See Fig 6 4 The sensor will be more sensitive to motion across its detection path than motion directly towards it See Fig 7 5 To reduce possible nuisances do not mount the fixture near a heat source like an air co...

Страница 4: ...SET FOR T0193 T0194 Glass Panel 9814CS 1 SET FOR T0195 T0196 Green Grounding Screw C Lock Nut F Wire Nut E Rubber Pad G Headless Screw D Bolt Nut H T0193 T0194 A 10 B 19 C 11 T0195 T0196 A 7 B 14 1 2 C 7 5 8 5 YEAR LIMITED WARRANTY All products are warranted to be free of defects in material and workmanship for five 5 years from date of purchase This warranty is limited to the correction of any su...

Отзывы: